This weekend we encountered a 3494 foible which 3494 customers should be
aware of...
The robotic actuator achieves vertical motion via a roughly 5' tall
steel helix. The helix is lubricated with a grease. Over time, the
grease dries out - and solidifies. The robot then strains to gain
elevation, which over-taxes the vertical drive motor and causes an
electrical Intervention Required. The associated panel message specifies
an IBM service call. They will respond by cleaning and re- lubricating
the shaft.
To prevent an outage of some hours, you may want to assure that your CE
is performing periodic re-lubrication of this assembly. One would think
that it would be on the list of PM tasks, but apparently it is not.
Other robotic library types may have a similar vulnerability.