A 3494 foible, FYI
2006-03-19 07:07:21
This weekend we encountered a 3494 foible which 3494 customers should
be aware of...
The robotic actuator achieves vertical motion via a roughly 5' tall
steel helix. The helix is lubricated with a grease. Over time, the
grease dries out - and solidifies. The robot then strains to gain
elevation, which over-taxes the vertical drive motor and causes an
electrical Intervention Required. The associated panel message
specifies an IBM service call. They will respond by cleaning and re-
lubricating the shaft.
To prevent an outage of some hours, you may want to assure that your
CE is performing periodic re-lubrication of this assembly. One would
think that it would be on the list of PM tasks, but apparently it is
not.
Other robotic library types may have a similar vulnerability.
Richard Sims
|
<Prev in Thread] |
Current Thread |
[Next in Thread>
|
- A 3494 foible, FYI,
Richard Sims <=
|
|
|