ADSM-L

Re: Corrupted LTO CM Index

2004-10-04 07:07:01
Subject: Re: Corrupted LTO CM Index
From: Bill Boyer <bill.boyer AT VERIZON DOT NET>
To: ADSM-L AT VM.MARIST DOT EDU
Date: Mon, 4 Oct 2004 07:06:20 -0400
They were all purchased summer 2003 as part of the whole order...x345
server..3853..40-tapes. So I would think they are IBM, but I'll try to find
out. I remember one tape in particular that would always go into ReadOnly I
finally had them remove it from the library.

Bill Boyer
"I haven't lost my mind -- it's backed up on tape somewhere." - ???

-----Original Message-----
From: ADSM: Dist Stor Manager [mailto:ADSM-L AT VM.MARIST DOT EDU]On Behalf Of
Lambelet,Rene,VEVEY,GLOBE Center CSC
Sent: Monday, October 04, 2004 4:17 AM
To: ADSM-L AT VM.MARIST DOT EDU
Subject: Re: Corrupted LTO CM Index


Hi, what type of tape is it ? Imation, IBM... ?

When did you get them, 2003 or sooner ?

We have to replace all Imation tapes delivered between 2001 and 2002 !! At
about one third of the tape, we get the tape in r/o by TSM because of EOD
missing and write errors.

                Reni LAMBELET
                NESTEC  SA
                GLOBE - Global Business Excellence
                Central Support Center
                SD/ESN
                Av. Nestli 55  CH-1800 Vevey (Switzerland)
                til +41 (0)21 924'35'43   fax +41 (0)21 924'45'89   local
REL-5 01
                mailto:rene.lambelet AT nestle DOT com

                This message is intended only for the use of the addressee
                and may contain information that is privileged and
confidential.




-----Original Message-----
From: ADSM: Dist Stor Manager [mailto:ADSM-L AT VM.MARIST DOT EDU]On Behalf Of
Bill Boyer
Sent: Saturday,2. October 2004 14:05
To: ADSM-L AT VM.MARIST DOT EDU
Subject: Corrupted LTO CM Index


I ran into this problem big time a couple weeks ago and Dave Canan posted an
excellent note about the corrupted index on LTO cartridges. Since then I've
had a couple tapes become corrupted. After the incident, I checked out all
my tapes and checked them in with CHECKLABEL=YES. This identified all the
tapes with existing corrupted index chips with the TAPEALERT messages. I
then MOVE DATA all these tapes and they were reused. Yesterday again I had a
tape that was checked in with CHECKL=YES that did not indicate a problem,
but this morning after being used as a copypool tape when it was dismounted
it for the ANR8950W message about a corrupted index.

What is causing this corruption?? I have updated the drives and library to
the latest firmware. There were no I/O errors or any other indications of a
problem. Is this tape just bad?? Before we were having SCSI errors on the
motherboard of the x345 server. We believe this caused the corruption, now
I'm not so sure.

Any help is greatly appreciated!

Bill Boyer
"An Optimist is just a pessimist with no job experience."  - Scott Adams

<Prev in Thread] Current Thread [Next in Thread>