Re: Quick backup stgp question
2004-09-29 06:54:57
Yes.
--
Mark Stapleton (stapleton AT berbee DOT com)
Berbee Information Networks
Office 262.521.5627
>-----Original Message-----
>From: ADSM: Dist Stor Manager [mailto:ADSM-L AT VM.MARIST DOT EDU] On
>Behalf Of Warren, Matthew (Retail)
>Sent: Wednesday, September 29, 2004 5:32 AM
>To: ADSM-L AT VM.MARIST DOT EDU
>Subject: Quick backup stgp question
>
>Hallo,
>
>Just confirming behaviour I think I'm seeing;
>
>We just had a backup storagepool process pre-empted. At the
>end of the backup process, some of the threads report
>'FAILURE', and hence our job script reports a failure.
>
>Running the backup stgp by hand immediatley afterwards, it
>finishes with 0 objects backed up, and reports success..
>
>So, am I right in assuming when a backup stgp process is
>pre-empted, it's workload is move onto the other backup stgp
>threads, so they will catch what would have been missed?
>
>
>Matt.
>
>
>___________________________ Disclaimer Notice
>__________________________ This message and any attachments
>are confidential and should only be read by those to whom they
>are addressed. If you are not the intended recipient, please
>contact us, delete the message from your computer and destroy
>any copies. Any distribution or copying without our prior
>permission is prohibited.
>
>Internet communications are not always secure and therefore
>Powergen Retail Limited does not accept legal responsibility
>for this message. The recipient is responsible for verifying
>its authenticity before acting on the contents. Any views or
>opinions presented are solely those of the author and do not
>necessarily represent those of Powergen Retail Limited.
>
>Registered addresses:
>
>Powergen Retail Limited, Westwood Way, Westwood Business Park,
>Coventry, CV4 8LG.
>Registered in England and Wales No: 3407430
>
>Telephone +44 (0) 2476 42 4000
>Fax +44 (0) 2476 42 5432
>
|
|
|