3590H1A SAN Failover
2003-12-09 17:07:27
Hello, everyone!
Here's what I got:
Server: pSeries 6M1
OS: AIX 4.3.3.10
Atape version: 8.3.6.0
ITSM: 5.1.6.4
Library: IBM 3494 w/8 3590H1A-FC drives
SAN Switches: Cisco MDS 9216 fw:1.2(2A)
fcs1 adapter is attached to SW-A. fcs2 is attached to SW-B.
rmt8 is attached to SW-A (port 0 on 3590 drive) and SW-B (port 1 on 3590
drive).
In AIX the drive is configured for alternate pathing and shows up as
follows.
rmt8 Available 7A-08-01-PRI IBM 3590 Tape Drive and Medium Changer(FCP)
rmt81 Available 71-08-01-ALT IBM 3590 Tape Drive and Medium Changer(FCP)
[BTW, rmt81 after doing rmdev -l rmt9 ; chdev -l rmt9 -a
new_name=rmt81.]
This all works fine. But to test the configuration I started a full DB
backup and then did the following:
1) after the DB backup process started writing to the tape, I pulled out
the fiber attached to port 0 of the drive. The DB backup stopped and
failed. I reattached the fiber.
2) after the DB backup process started writing to the tape, I pulled out
the fiber on fcs1. The DB backup paused and then after a few seconds
continued and completed successfully. I reattached the fiber.
So, I was wondering if I am missing something to make the first scenario
not successful? Any insight would be appreciated.
TIA
Mahesh
|
<Prev in Thread] |
Current Thread |
[Next in Thread> |
- 3590H1A SAN Failover,
Mahesh Tailor <=
|
|
|