Hi all,
07/24/03 15:35:06 ANR8788W Unable to read the barcode of cartridge in
slot-id 1063 in library 3584LIB; loading in drive to
read label.
07/24/03 15:35:06 ANR8300E I/O error on library 3584LIB (OP=00006C03,
CC=207, KEY=05, ASC=30, ASCQ=00,
SENSE=70.00.05.00.00.0-
0.00.0A.00.00.00.00.30.00.00.C0.00.04.,
Description=Dev-
ice is not in a state capable of performing request).
Refer to Appendix D in the 'Messages' manual for
recommended action.
07/24/03 15:35:06 ANR2017I Administrator KAREL issued command: QUERY
PROCESS
07/24/03 15:35:06 ANR9999D mmsscsi.c(9401): ThreadId<28> Could not move
volume NOT KNOWN from slot 1063 to slot 262.
07/24/03 15:35:07 ANR8460E AUDIT LIBRARY process for library 3584LIB
failed.
07/24/03 15:35:07 ANR0985I Process 32 for AUDIT LIBRARY running in the
BACKGROUND completed with completion state FAILURE at
15:35:07.
os'ses=AIX + win2k
TSM=4.2.2.13 (AIX) + 5.1.7.0 (win2k)
Libraries=both 3584
On both sites we had some problems with tapes stuck in drives. On both sites
we had to do audit libraries to get TSM in synch with the libraries. While
the tapes were stuck in the drive, the audit library failes and now one of
the slots is empty (tape was in the drive and is completely gone) and still
the audit fails. Has anyone seen this type of behavour? Is it a TSM thing
(don't think so because of the version difference between sites) or has
something been altered in the microcode of the library what changes things?
Regard,
Karel
|