ADSM-L

STK L700 CHECKIN SEARCH=BULK

2002-05-08 16:43:06
Subject: STK L700 CHECKIN SEARCH=BULK
From: "Tait, Joel" <Joel.Tait AT CCRA-ADRC.GC DOT CA>
Date: Wed, 8 May 2002 16:42:45 -0400
Hi,
I have a STK L700 (Rev. 2.36) tape library with 9840 tape drive. TSM 4.2 on
a Win2000.
I can checkout tapes but I get the following error when I try to checkin
tapes:

ANR2017I Administrator JET121 issued command: CHECKIN libvol l700_library
search=bulk status=pri checklabel=barcode
ANR0984I Process 22 for CHECKIN LIBVOLUME started in the BACKGROUND at
08:49:11.
ANR8422I CHECKIN LIBVOLUME: Operation for library L700_LIBRARY started as
process 22.
ANR8373I 003: Fill the bulk entry/exit port of library L700_LIBRARY with all
ECARTRIDGE volumes to be processed within 60 minute(s); issue 'REPLY' along
with the request ID when ready.
ANR2017I Administrator JET121 issued command: REPLY 003
ANR8499I Command accepted.
ANR8300E I/O error on library L700_LIBRARY (OP=8401C05C, CC=210, KEY=06,
ASC=29, ASCQ=02,
SENSE=70.00.06.00.00.00.00.0C.00.00.00.00.29.02.00.00.00.00.00.00.,
Description=The device was reset due to device power-up, SCSI bus reset, or
manual tape load/eject).  Refer to Appendix D in the 'Messages' manual for
recommended action.

Thanks

Joel Tait
<Prev in Thread] Current Thread [Next in Thread>