ADSM-L

Antwort: Re: Antwort: Re: Win NT 4 Installer Problems with several TSM Clients

2002-01-29 01:07:07
Subject: Antwort: Re: Antwort: Re: Win NT 4 Installer Problems with several TSM Clients
From: Holger Bitterlich <holger.bitterlich AT SK-KOELN DOT DE>
Date: Mon, 28 Jan 2002 13:58:21 +0100
Andy,

ok, here is the compete log:

=== Verbose logging started: 28.01.02  13:52:44  Build type: SHIP UNICODE
2.00.2600.00  Calling process: C:\WINNT\System32\MSIEXEC.EXE ===
MSI (c) (FC:A7): Resetting cached policy values
MSI (c) (FC:A7): Machine policy value 'Debug' is 0
MSI (c) (FC:A7): ******* RunEngine:
           ******* Product: D:
\TEMP\Remove_After_Install\TSM_BA_Client\Tivoli Storage Manager Client.msi
           ******* Action:
           ******* CommandLine: **********
MSI (c) (FC:A7): Machine policy value 'DisableUserInstalls' is 0
MSI (c) (FC:A7): End dialog not enabled
MSI (c) (FC:A7): Original package ==> D:
\TEMP\Remove_After_Install\TSM_BA_Client\Tivoli Storage Manager Client.msi
MSI (c) (FC:A7): Package we're running from ==> C:\TEMP\1e61b1e.msi
MSI (c) (FC:A7): APPCOMPAT: looking for appcompat database entry with
ProductCode '{BBE9D598-7861-11D4-BD76-002035405D21}'.
MSI (c) (FC:A7): APPCOMPAT: no matching ProductCode found in database.
MSI (c) (FC:A7): Machine policy value 'TransformsSecure' is 0
MSI (c) (FC:A7): User policy value 'TransformsAtSource' is 0
MSI (c) (FC:A7): Looking for file transform: D:
\TEMP\Remove_After_Install\TSM_BA_Client\1031.MST
MSI (c) (FC:A7): Validating transform 'D:
\TEMP\Remove_After_Install\TSM_BA_Client\1031.MST' with validation bits 0x0
MSI (c) (FC:A7): Transform 'D:
\TEMP\Remove_After_Install\TSM_BA_Client\1031.MST' is valid.
MSI (c) (FC:A7): Note: 1: 2262 2: Patch 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: PatchPackage 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: _Tables 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: _Columns 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: File 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: PatchPackage 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: Patch 3: -2147287038
MSI (c) (FC:A7): TRANSFORM: 'PatchPackage' table is missing or empty.  No
pre-transform fixup necessary.
MSI (c) (FC:A7): TRANSFORM: Applying regular transform to database.
MSI (c) (FC:A7): Note: 1: 2262 2: _Tables 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: _Columns 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: AdminExecuteSequence 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: Condition 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: AdminUISequence 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: AdvtExecuteSequence 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: AdvtUISequence 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: AppId 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: AppSearch 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: BBControl 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: Billboard 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: BindImage 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: File 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: CCPSearch 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: CheckBox 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: Class 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: Component 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: Icon 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: ProgId 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: ComboBox 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: CompLocator 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: Complus 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: Directory 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: ModuleComponents 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: ModuleSignature 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: CreateFolder 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: CustomAction 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: ModuleDependency 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: DrLocator 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: DuplicateFile 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: Environment 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: Extension 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: MIME 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: FeatureComponents 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: Font 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: IniFile 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: InstallShield 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: IniLocator 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: InstallExecuteSequence 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: InstallUISequence 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: IsolatedComponent 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: ListBox 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: ListView 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: LockPermissions 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: MoveFile 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: ODBCAttribute 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: ODBCDriver 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: ODBCDataSource 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: ODBCSourceAttribute 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: ODBCTranslator 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: Patch 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: PatchPackage 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: PublishComponent 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: Registry 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: RegLocator 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: RemoveFile 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: RemoveIniFile 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: RemoveRegistry 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: ReserveCost 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: SelfReg 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: ServiceControl 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: ServiceInstall 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: Shortcut 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: Signature 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: TextStyle 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: TypeLib 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: Upgrade 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: Verb 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: _Validation 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: ISBillBoard 3: -2147287038
MSI (c) (FC:A7): Note: 1: 2262 2: _MsiPatchTransformView 3: -2147287038
MSI (c) (FC:A7): APPCOMPAT: looking for appcompat database entry with
ProductCode '{BBE9D598-7861-11D4-BD76-002035405D21}'.
MSI (c) (FC:A7): APPCOMPAT: no matching ProductCode found in database.
MSI (c) (FC:A7): Transforms are not secure.
MSI (c) (FC:A7): Transforming table Property.

MSI (c) (FC:A7): Note: 1: 2262 2: Control 3: -2147287038
MSI (c) (FC:A7): Transforming table Control.

MSI (c) (FC:A7): Command Line: TRANSFORMS=1031.MST CURRENTDIRECTORY=D:
\TEMP\Remove_After_Install\TSM_BA_Client CLIENTUILEVEL=0
CLIENTPROCESSID=508 %HOMEPATH=\ %HOMEDRIVE=C: %HOMESHARE=
MSI (c) (FC:A7): Product Code passed to Engine.Initialize:           ''
MSI (c) (FC:A7): Product Code from property table before transforms:
'{BBE9D598-7861-11D4-BD76-002035405D21}'
MSI (c) (FC:A7): Product Code from property table after transforms:
'{BBE9D598-7861-11D4-BD76-002035405D21}'
MSI (c) (FC:A7): Product not registered: beginning first-time install
MSI (c) (FC:A7): Entering CMsiConfigurationManager::SetLastUsedSource.
MSI (c) (FC:A7): User policy value 'SearchOrder' is 'nmu'
MSI (c) (FC:A7): Adding new sources is allowed.
MSI (c) (FC:A7): Package name extracted from package path: 'Tivoli Storage
Manager Client.msi'
MSI (c) (FC:A7): Transforming table Error.

MSI (c) (FC:A7): Note: 1: 2729
MSI (c) (FC:A7): Note: 1: 2729
MSI (c) (FC:A7): Note: 1: 2262 2: AdminProperties 3: -2147287038
MSI (c) (FC:A7): Machine policy value 'DisableMsi' is 0
MSI (c) (FC:A7): Machine policy value 'AlwaysInstallElevated' is 0
MSI (c) (FC:A7): User policy value 'AlwaysInstallElevated' is 0
MSI (c) (FC:A7): Product installation will be elevated because user is
admin and product is being installed per-machine.
MSI (c) (FC:A7): Running product '{BBE9D598-7861-11D4-BD76-002035405D21}'
with elevated privileges: Product is assigned.
MSI (c) (FC:A7): TRANSFORMS property is now: D:
\TEMP\Remove_After_Install\TSM_BA_Client\1031.MST
MSI (c) (FC:A7): SHFOLDER::SHGetFolderPath returned: C:
\WINNT\Profiles\xadtsm\Anwendungsdaten
MSI (c) (FC:A7): SHFOLDER::SHGetFolderPath returned: C:
\WINNT\Profiles\xadtsm\Favoriten
MSI (c) (FC:A7): SHFOLDER::SHGetFolderPath returned: C:
\WINNT\Profiles\xadtsm\Netzwerkumgebung
MSI (c) (FC:A7): SHFOLDER::SHGetFolderPath returned: C:
\WINNT\Profiles\xadtsm\Eigene Dateien
MSI (c) (FC:A7): SHFOLDER::SHGetFolderPath returned: C:
\WINNT\Profiles\xadtsm\Druckumgebung
MSI (c) (FC:A7): SHFOLDER::SHGetFolderPath returned: C:
\WINNT\Profiles\xadtsm\Recent
MSI (c) (FC:A7): SHFOLDER::SHGetFolderPath returned: C:
\WINNT\Profiles\xadtsm\SendTo
MSI (c) (FC:A7): SHFOLDER::SHGetFolderPath returned: C:\WINNT\ShellNew
MSI (c) (FC:A7): SHFOLDER::SHGetFolderPath returned: C:\WINNT\Profiles\All
Users\Anwendungsdaten
MSI (c) (FC:A7): SHFOLDER::SHGetFolderPath returned: C:
\WINNT\Profiles\xadtsm\Local Settings\Anwendungsdaten
MSI (c) (FC:A7): SHFOLDER::SHGetFolderPath returned: C:
\WINNT\Profiles\xadtsm\Eigene Dateien\Eigene Bilder
MSI (c) (FC:A7): SHFOLDER::SHGetFolderPath returned: C:\WINNT\Profiles\All
Users\Startmenü\Programme\Verwaltung
MSI (c) (FC:A7): SHFOLDER::SHGetFolderPath returned: C:\WINNT\Profiles\All
Users\Startmenü\Programme\Autostart
MSI (c) (FC:A7): SHFOLDER::SHGetFolderPath returned: C:\WINNT\Profiles\All
Users\Startmenü\Programme
MSI (c) (FC:A7): SHFOLDER::SHGetFolderPath returned: C:\WINNT\Profiles\All
Users\Startmenü
MSI (c) (FC:A7): SHFOLDER::SHGetFolderPath returned: C:\WINNT\Profiles\All
Users\Desktop
MSI (c) (FC:A7): SHFOLDER::SHGetFolderPath returned: C:
\WINNT\Profiles\xadtsm\Startmenü\Programme\Verwaltung
MSI (c) (FC:A7): SHFOLDER::SHGetFolderPath returned: C:
\WINNT\Profiles\xadtsm\Startmenü\Programme\Autostart
MSI (c) (FC:A7): SHFOLDER::SHGetFolderPath returned: C:
\WINNT\Profiles\xadtsm\Startmenü\Programme
MSI (c) (FC:A7): SHFOLDER::SHGetFolderPath returned: C:
\WINNT\Profiles\xadtsm\Startmenü
MSI (c) (FC:A7): SHFOLDER::SHGetFolderPath returned: C:
\WINNT\Profiles\xadtsm\Desktop
MSI (c) (FC:A7): SHFOLDER::SHGetFolderPath returned: C:\WINNT\Fonts
MSI (c) (FC:A7): Note: 1: 2898 2: MS Sans Serif 3: MS Sans Serif 4: 0 5: 16
MSI (c) (FC:A7): MSCOREE not loaded loading copy from system32
MSI (c) (FC:A7): Note: 1: 1402 2: HKEY_CURRENT_USER\Software\Microsoft\MS
Setup (ACME)\User Info 3: 2
MSI (c) (FC:A7): Note: 1: 1402 2: HKEY_CURRENT_USER\Software\Microsoft\MS
Setup (ACME)\User Info 3: 2
=== Protokollierung gestartet: 28.01.02  13:52:50 ===
MSI (c) (FC:A7): Machine policy value 'DisableRollback' is 0
MSI (c) (FC:A7): User policy value 'DisableRollback' is 0
MSI (c) (FC:A7): Doing action: INSTALL
MSI (c) (FC:A7): Transforming table ActionText.

Aktion gestartet um 13:52:50: INSTALL.
MSI (c) (FC:A7): UI Sequence table 'InstallUISequence' is present and
populated.
MSI (c) (FC:A7): Running UISequence
MSI (c) (FC:A7): Doing action: EngineStartup
Aktion gestartet um 13:52:50: EngineStartup.
MSI (c) (FC:A7): Transforming table Binary.

MSI (c) (FC:A7): Creating MSIHANDLE (1) of type 790542 for thread 423
Aktion beendet um 13:52:51: EngineStartup. Rückgabewert 1.
MSI (c) (FC:A7): Doing action: StartUp
Aktion gestartet um 13:52:51: StartUp.
MSI (c) (FC:A7): Transforming table Binary.

MSI (c) (FC:A7): Creating MSIHANDLE (2) of type 790542 for thread 423
Aktion beendet um 13:52:54: StartUp. Rückgabewert 3.
MSI (c) (FC:A7): Doing action: SetupCompleteError
Aktion gestartet um 13:52:54: SetupCompleteError.
Information 2898. Tahoma8, Tahoma, 0
Information 2898. TahomaBold10, Tahoma, 0
Aktion 13:52:59: SetupCompleteError. Dialog created
Aktion beendet um 13:53:36: SetupCompleteError. Rückgabewert 2.
Aktion beendet um 13:53:36: INSTALL. Rückgabewert 3.
MSI (c) (FC:A7): Lost connection to custom action server process.
Attempting to regenerate.




at this stage the install process seems to be ended, but after a couple of
minutes here comes the rest:




MSI (c) (D9:A6): Note: 1: 2262 2: Control 3: -2147287038
MSI (c) (D9:A6): Transforming table Control.

Property(C): DiskPrompt = [1]
Property(C): Registration = No
Property(C): UpgradeCode = {D9CD5635-445F-4B37-8FF6-6717519F096B}
Property(C): ProductName = Tivoli Storage Manager Client
Property(C): DialogCaption = InstallShield for Windows Installer
Property(C): ProductVersion = 04.01.0100
Property(C): ProductID = None
Property(C): AppDataFolder = C:\WINNT\Profiles\xadtsm\Anwendungsdaten\
Property(C): CommonFilesFolder = C:\Programme\Gemeinsame Dateien\
Property(C): DesktopFolder = C:\WINNT\Profiles\All Users\Desktop\
Property(C): FontsFolder = C:\WINNT\Fonts\
Property(C): FavoritesFolder = C:\WINNT\Profiles\xadtsm\Favoriten\
Property(C): NetHoodFolder = C:\WINNT\Profiles\xadtsm\Netzwerkumgebung\
Property(C): PersonalFolder = C:\WINNT\Profiles\xadtsm\Eigene Dateien\
Property(C): PrintHoodFolder = C:\WINNT\Profiles\xadtsm\Druckumgebung\
Property(C): ProgramFilesFolder = C:\Programme\
Property(C): ProgramMenuFolder = C:\WINNT\Profiles\All
Users\Startmenü\Programme\
Property(C): RecentFolder = C:\WINNT\Profiles\xadtsm\Recent\
Property(C): SendToFolder = C:\WINNT\Profiles\xadtsm\SendTo\
Property(C): StartMenuFolder = C:\WINNT\Profiles\All Users\Startmenü\
Property(C): StartupFolder = C:\WINNT\Profiles\All
Users\Startmenü\Programme\Autostart\
Property(C): System16Folder = C:\WINNT\System\
Property(C): SystemFolder = C:\WINNT\System32\
Property(C): TempFolder = C:\TEMP\
Property(C): TemplateFolder = C:\WINNT\ShellNew\
Property(C): WindowsFolder = C:\WINNT\
Property(C): SOURCEDIR = D:\TEMP\Remove_After_Install\TSM_BA_Client\
Property(C): AdminToolsFolder = C:\WINNT\Profiles\All
Users\Startmenü\Programme\Verwaltung\
Property(C): CommonAppDataFolder = C:\WINNT\Profiles\All
Users\Anwendungsdaten\
Property(C): LocalAppDataFolder = C:\WINNT\Profiles\xadtsm\Local
Settings\Anwendungsdaten\
Property(C): MyPicturesFolder = C:\WINNT\Profiles\xadtsm\Eigene
Dateien\Eigene Bilder\
Property(C): VersionNT = 400
Property(C): AdminUser = 1
Property(C): NewFolder = NewFolder-NOTUSED
Property(C): DefaultUIFont = Tahoma8
Property(C): AgreeToLicense = No
Property(C): ProgressType0 = install
Property(C): _IsSetupTypeMin = Typical
Property(C): _IsMaintenance = Change
Property(C): ARPHELPLINK = http://www.tivoli.com/support/handbook
Property(C): ARPHELPTELEPHONE = 1-800-237-5511
Property(C): DiskSerial = 1234-5678
Property(C): Display_IsBitmapDlg = 1
Property(C): ErrorDialog = SetupError
Property(C): InstallChoice = AR
Property(C): INSTALLLEVEL = 100
Property(C): Manufacturer = Tivoli
Property(C): PIDTemplate = 12345<###-%%%%%%%>@@@@@
Property(C): RebootYesNo = Yes
Property(C): ReinstallFileVersion = o
Property(C): ReinstallRepair = r
Property(C): SetupType = Typical
Property(C): ApplicationUsers = AllUsers
Property(C): ProgressType1 = Installing
Property(C): ProgressType2 = installed
Property(C): ProgressType3 = installs
Property(C): ReinstallModeText = omus
Property(C): ARPNOREPAIR = 0
Property(C): ARPURLINFOABOUT =
http://www.tivoli.com/products/index/storage_mgr
Property(C): ARPURLUPDATEINFO =
http://www.tivoli.com/products/index/storage_mgr/adsercli.htm#AF
Property(C): ProductLanguage = 1031
Property(C): ProductCode = {BBE9D598-7861-11D4-BD76-002035405D21}
Property(C): ALLUSERS = 1
Property(C): TSMSOURCEDIR = NO
Property(C): TSM_PRODUCT_LANGUAGE = 1033
Property(C): SecureCustomProperties = TSMREMOVEMAINBA
Property(C): USERNAME = PC-Benutzerservice
Property(C): COMPANYNAME = Stadtsparkasse Köln
Property(C): PackageCode = {20D0AD1C-617F-11D4-BD65-002035405D21}
Property(C): TRANSFORMS = D:
\TEMP\Remove_After_Install\TSM_BA_Client\1031.MST
Property(C): CURRENTDIRECTORY = D:\TEMP\Remove_After_Install\TSM_BA_Client
Property(C): ProductState = -1
Property(C): PackagecodeChanging = 1
Property(C): VersionDatabase = 110
Property(C): CLIENTUILEVEL = 0
Property(C): CLIENTPROCESSID = 473
Property(C): VersionMsi = 2.00
Property(C): WindowsBuild = 1381
Property(C): ServicePackLevel = 6
Property(C): MsiNTProductType = 3
Property(C): WindowsVolume = C:\
Property(C): Intel = 6
Property(C): PhysicalMemory = 255
Property(C): VirtualMemory = 429
Property(C): LogonUser = XADTSM
Property(C): UserSID = S-1-5-21-1986952986-1294095227-634672238-7390
Property(C): UserLanguageID = 1031
Property(C): ComputerName = WA19973733
Property(C): SystemLanguageID = 1031
Property(C): ScreenX = 800
Property(C): ScreenY = 600
Property(C): CaptionHeight = 19
Property(C): BorderTop = 1
Property(C): BorderSide = 1
Property(C): TextHeight = 16
Property(C): ColorBits = 8
Property(C): Time = 13:55:13
Property(C): Date = 28.01.02
Property(C): Privileged = 1
Property(C): DATABASE = C:\TEMP\1e0b8e3.msi
Property(C): OriginalDatabase = D:
\TEMP\Remove_After_Install\TSM_BA_Client\Tivoli Storage Manager Client.msi
Property(C): SourceDir = D:\TEMP\Remove_After_Install\TSM_BA_Client\
Property(C): VersionHandler = 2.00
Property(C): UILevel = 5
Property(C): ACTION = INSTALL
Property(C): EXECUTEACTION = INSTALL
=== Protokollierung beendet: 28.01.02  13:55:13 ===
MSI (c) (D9:A6): Note: 1: 1708
MSI (c) (D9:A6): Transforming table Error.

MSI (c) (D9:A6): Transforming table Error.

MSI (c) (D9:A6): Produkt: Tivoli Storage Manager Client --
Installationsvorgang fehlgeschlagen.

MSI (c) (D9:A6): Grabbed execution mutex.
MSI (c) (D9:A6): Cleaning up uninstalled install packages, if any exist
MSI (c) (D9:A6): MainEngineThread is returning 1603
=== Verbose logging stopped: 28.01.02  13:55:13 ===


--
Holger Bitterlich
Holger Bitterlich
Stadtsparkasse Köln
Organisation und Datenverarbeitung
Telefon: (0221) 226 - 54 18
Fax: (0221) 226 - 51 00
mailto:Holger.Bitterlich AT sk-koeln DOT de
http://www.sk-koeln.de

"ADSM: Dist Stor Manager" <ADSM-L AT VM.MARIST DOT EDU> schrieb am 25.01.2002
15:49:21:

> For the purposes of diagnosing install problems, we like to see all
> logging options activated:
>
>    setup /v"/l*v setup.log"
>
> Regards,
>
> Andy
>
> Andy Raibeck
> IBM Software Group
> Tivoli Storage Manager Client Development
> Internal Notes e-mail: Andrew Raibeck/Tucson/IBM@IBMUS
> Internet e-mail: storman AT us.ibm DOT com
>
> The only dumb question is the one that goes unasked.
> The command line is your friend.
> "Good enough" is the enemy of excellence.

Da E-Mails leicht unter fremdem Namen erstellt oder manipuliert werden
koennen, muessen wir zu Ihrem und unserem Schutz die rechtliche
Verbindlichkeit der vorstehenden Erklaerungen ausschliessen. Die fuer die
Stadtsparkasse Koeln geltenden Regeln ueber die Verbindlichkeit von
rechtsgeschaeftlichen Erklaerungen mit verpflichtendem Inhalt bleiben
unberuehrt.

<Prev in Thread] Current Thread [Next in Thread>
  • Antwort: Re: Antwort: Re: Win NT 4 Installer Problems with several TSM Clients, Holger Bitterlich <=