ADSM-L

Re: Why doesn't TSM use this tape volume?

2001-02-16 14:39:27
Subject: Re: Why doesn't TSM use this tape volume?
From: David Longo <David.Longo AT HEALTH-FIRST DOT ORG>
Date: Fri, 16 Feb 2001 14:39:37 -0500
Nothing obvious from your info.  I would do a:
move data C20139
This will either move the data off this tape and put it back in scratch pool or 
give some info in actlog as to any problem with it.



David B. Longo
System Administrator
Health First, Inc.
3300 Fiske Blvd.
Rockledge, FL 32955-4305
PH      321.434.5536
Pager  321.634.8230
Fax:    321.434.5525
david.longo AT health-first DOT org


>>> snow AT TELLEO DOT COM 02/16/01 02:27PM >>>
I have a couple of tape volumes which TSM does not use, and I don't
understand why.  The server is 4.1.2 on AIX 4.3.3.  The library is a
Spectra 10000 (AIT BullFrog).  One of the volumes in question is
C20139.  It's only .6% full, but hasn't been touched since last December
12th.  Colocate is "No" for the TAPE storagepool.  Why doesn't TSM continue
to fill this volume and how do I correct the situation?  Thanks for any
insights.

tsm: TSM>q vol

Volume Name               Storage      Device      Estimated    Pct   Volume
                           Pool Name    Class Name   Capacity   Util   Status
                                                         (MB)
------------------------  -----------  ----------  ---------  -----  --------
--------
/dev/rtsmstg1lv           DISK1        DISK         10,016.0   57.5  
/dev/rtsmstg1lv           DISK1        DISK         10,016.0   57.5  On-Line
/dev/rtsmstg2lv           DISK1        DISK         10,016.0   64.0  On-Line
C20138                    TAPE         AIT-TAPE     57,085.1   41.1    Full
C20139                    TAPE         AIT-TAPE     81,920.0    0.6  Filling
C20140                    TAPE         AIT-TAPE     73,035.4   52.1    Full
C20145                    TAPE         AIT-TAPE     71,070.3   45.5    Full
C20148                    TAPE         AIT-TAPE     77,077.4   41.3    Full
C20182                    TAPE         AIT-TAPE     81,920.0    0.3  Filling
C20186                    TAPE         AIT-TAPE     75,440.0   43.4    Full
C20187                    TAPE         AIT-TAPE     70,521.2   55.7    Full
C20193                    TAPE         AIT-TAPE     65,248.8   45.1    Full
C20194                    TAPE         AIT-TAPE     81,920.0   40.3  Filling
C20200                    TAPE         AIT-TAPE     81,920.0    1.4  Filling
tsm: TSM>q vol c20139 f=d

                    Volume Name: C20139
              Storage Pool Name: TAPE
              Device Class Name: AIT-TAPE
        Estimated Capacity (MB): 81,920.0
                       Pct Util: 0.6
                  Volume Status: Filling
                         Access: Read/Write
         Pct. Reclaimable Space: 3.9
                Scratch Volume?: Yes
                In Error State?: No
       Number of Writable Sides: 1
        Number of Times Mounted: 2
              Write Pass Number: 1
      Approx. Date Last Written: 12/12/00   12:58:22
         Approx. Date Last Read: 12/12/00   14:29:48
            Date Became Pending:
         Number of Write Errors: 0
          Number of Read Errors: 0
                Volume Location:
Last Update by (administrator):
          Last Update Date/Time:
12/12/00   12:50:41


Richard Snow
snow AT telleo DOT com 



"MMS <health-first.org>" made the following
 annotations on 02/16/01 14:44:48
------------------------------------------------------------------------------
This message is for the named person's use only.  It may contain confidential, 
proprietary, or legally privileged information.  No confidentiality or 
privilege is waived or lost by any mistransmission.  If you receive this 
message in error, please immediately delete it and all copies of it from your 
system, destroy any hard copies of it, and notify the sender.  You must not, 
directly or indirectly, use, disclose, distribute, print, or copy any part of 
this message if you are not the intended recipient.  Health First reserves the 
right to monitor all e-mail communications through its networks.  Any views or 
opinions expressed in this message are solely those of the individual sender, 
except (1) where the message states such views or opinions are on behalf of a 
particular entity;  and (2) the sender is authorized by the entity to give such 
views or opinions.
This message is for the named person's use only.  It may contain confidential, 
proprietary, or legally privileged information.  No confidentiality or 
privilege is waived or lost by any mistransmission.  If you receive this 
message in error, please immediately delete it and all copies of it from your 
system, destroy any hard copies of it, and notify the sender.  You must not, 
directly or indirectly, use, disclose, distribute, print, or copy any part of 
this message if you are not the intended recipient.  Health First reserves the 
right to monitor all e-mail communications through its networks.  Any views or 
opinions expressed in this message are solely those of the individual sender, 
except (1) where the message states such views or opinions are on behalf of a 
particular entity;  and (2) the sender is authorized by the entity to give such 
views or opinions.

 ===========================================================================
<Prev in Thread] Current Thread [Next in Thread>