Check SMITTY and talk with your CE --- maybe look up and decode the error
data; you may need to redefine the devices to AIX, make sure your AIX
drivers are installed, run cfgmgr (rather than manually defining devices to
AIX), then delete and re-do DEFINEs (LIBR and DRIVE) to TSM. If smitty
hangs, you gotta reboot the machine --- that can happen if someone's been
popping serial cables/options while the system is running.
Regards,
Don
Don France
Technical Architect, P.A.C.E.
San Jose, CA
mailto:dfrance AT pacbell DOT net
PACE - http://www.pacepros.com
Bus-Ph: (408) 257-3037
> -----Original Message-----
> From: Marc Layne [mailto:mlayne AT FARITEC.CO DOT ZA]
> Sent: Thursday, February 03, 2000 5:14 AM
> To: ADSM-L AT VM.MARIST DOT EDU
> Subject: Error defining 3590 library
>
>
> Hi all
> I am getting the following error when trying to define an
> 3590 automated
> (SCSI) library. I have checked the system cansee the device
> (/dev/rmtx)
> and i am able to tar to the devices so no problem there.
> Versions: TSM 3.7.0
> AIX version 4.3.2
> Tape : 3590 B11
> Has anyone seen this before...
> All help greatly appreciated....
>
>
> Date/Time Message
>
> --------------------
> ----------------------------------------------------------
> 020300 12:12:18 ANR8300E I/O error on library 3590LIB1
> (OP=00006C06,
> CC=207, KEY=FF, ASC=FF, ASCQ=FF,
> SENSE=**NONE**,
>
> Description=Device is not in a state capable of
>
> performing request). Refer to
> Appendix B in the
>
> 'Messages' manual for recommended action.
>
> 020300 12:12:18 ANR8418E DEFINE LIBRARY: An I/O error occurred
> while
> accessing library 3590LIB1.
>
> 020300 12:16:18 ANR8300E I/O error on library 3590LIB1
> (OP=00006C06,
> CC=207, KEY=FF, ASC=FF, ASCQ=FF,
> SENSE=**NONE**,
>
> Description=Device is not in a state capable of
>
> performing request). Refer to
> Appendix B in the
>
> 'Messages' manual for recommended action.
>
> 020300 12:16:18 ANR8418E DEFINE LIBRARY: An I/O error occurred
> while
> accessing library 3590LIB1.
>
> 020300 13:11:33 ANR8300E I/O error on library 3590LIB1
> (OP=00006C06,
> CC=207, KEY=FF, ASC=FF, ASCQ=FF,
> SENSE=**NONE**,
>
> Description=Device is not in a state capable of
>
> performing request). Refer to
> Appendix B in the
>
> 'Messages' manual for recommended action.
>
> 020300 13:11:33 ANR8418E DEFINE LIBRARY: An I/O error occurred
> while
> accessing library 3590LIB1.
>
> 020300 13:11:51 ANR2017I Administrator ADMIN issued
> command: QUERY
> ACTLOG
> s=error
>
>
>
> Marc Anthony Layne
>
> RS/6000 Product Manager
> Faritec (Pty) Ltd.
> Mail to: mlayne AT faritec.co DOT za
> Tel: +27 21 7629702 Mobile: +27 82 4169086
> Fax: +27 21 7629737
> "You only live once.. but if you do it right once is enough...."
>
|