Use Version 3.1.2 of ADSM/400 and define your 3590 with a ESTCAP of 30G and
FORMAT=DRIVE...
Run a client backup, migrate your data to tape and when the EOT is reached,
the ESTCAP value is re-ajusted to the real Capacity and marks the tape as
FULL.
It is important to note my tests were with Client Compression turnned off...
adsm> q vol 002054 f=d
VOLUME NAME: 002054
STORAGE POOL NAME: TAPETEST
DEVICE CLASS NAME: ADSM3590X
ESTIMATED CAPACITY (MB): 12,457.4
PCT UTIL: 100.0
VOLUME STATUS: FULL
ACCESS: READ/WRITE
PCT. RECLAIMABLE SPACE: 0.0
SCRATCH VOLUME?: YES
IN ERROR STATE?: NO
NUMBER OF WRITABLE SIDES: 1
NUMBER OF TIMES MOUNTED: 3
WRITE PASS NUMBER: 1
APPROX. DATE LAST WRITTEN: 01/06/2000 11:13:42
APPROX. DATE LAST READ: 01/05/2000 15:16:35
DATE BECAME PENDING:
NUMBER OF WRITE ERRORS: 0
NUMBER OF READ ERRORS: 0
VOLUME LOCATION:
LAST UPDATE BY (ADMINISTRATOR):
LAST UPDATE DATE/TIME: 01/05/2000 15:16:33
adsm> q vol
VOLUME NAME STORAGE DEVICE ESTIMATED PCT VOLUME
POOL NAME CLASS NAME CAPACITY UTIL STATUS
(MB)
------------------------ ----------- ---------- --------- ----- -------
-
-
/DATA/ADSMDATA.001 DISKPOOL DISK 2,047.0 28.5 ON-LINE
/DATA/ADSMDATA.001 DISKPOOL DISK 2,047.0 28.5 ON-LINE
/DATA/ADSMDATA.002 DISKPOOL DISK 2,047.0 33.4 ON-LINE
002054 TAPETEST ADSM3590X 12,457.4 100.0 FULL
002056 TAPETEST ADSM3590X 30,720.0 0.0 FILLING
adsm>
Frederic Landreville email: landrefl AT yahoo DOT com
Lead Technical Analyst --- Yahoo Messenger Id: LANDREFL
R.J. Reynolds International B.V. (Hilversum) Geneva Branch
14, Chemin Rieu CH-1211 Geneva 17
Switzerland
Tel: +41-22-703-0323 Fax: +41-22-703-0324
"FAILURE IS NOT AN OPTION. It comes bundled with the software."
|