ADSM-L

Re: IBM 3494 and problems with defect cartridges

1999-01-27 18:01:34
Subject: Re: IBM 3494 and problems with defect cartridges
From: Trevor Foley <Trevor.Foley AT BANKERSTRUST.COM DOT AU>
Date: Thu, 28 Jan 1999 10:01:34 +1100
G'day,

There is a 'nicer' solution. These volumes should have an 3494 category of
FFFA, right? If you do a:

        mtlib -l /dev/lmcp0 -C -s FFFA -t FFFB -V volser

that should fix it. The FFFA category is 'manually ejected' and the FFFB
category means 'purge volume from inventory'.

For those of you that have the 3494: Practical Guide redbook, I'd suggest
that you update the list of categories documented in Appendix A with this
option.

I learnt this piece of magic from a post to this list by Ben Bullock some
time back.


Trevor

<Prev in Thread] Current Thread [Next in Thread>