Author: George Sinclair - NOAA Federal <george.sinclair AT NOAA DOT GOV>
Date: Tue, 10 Sep 2013 14:19:57 -0400
Let's say you'll have a number of file systems like /disk/user1, /disk/user2, etc. You never know when a new one might get created. Is there a way to have these automatically get added to the backups
Author: "Roberts, Justin (GE, Appl & Light)" <Justin.Roberts2 AT GE DOT COM>
Date: Wed, 11 Sep 2013 14:53:44 +0000
We are currently upgrading our environment from 7.6 to 8.0. On several occasions when installing 8.0 client on 32-bit Windows 2003 servers the install gets to the end and is unable to start the servi
Author: bingo <networker-forum AT BACKUPCENTRAL DOT COM>
Date: Thu, 12 Sep 2013 02:18:16 -0700
If you have verified that the service runs as "Local System" account, i am pretty sure that deleting/renaming the ..\nsr\res\nsrladb directory will resolve the issue. I have had a bunch of problems w
Author: bingo <networker-forum AT BACKUPCENTRAL DOT COM>
Date: Thu, 12 Sep 2013 02:22:03 -0700
I do not know any other easy fix but a true separation of executables and application data to be stored on different volumes. In general this is best practice anyway. +-- +--
Author: Michael Leone <Michael.Leone AT PHA.PHILA DOT GOV>
Date: Thu, 12 Sep 2013 15:25:44 -0400
We've finally gotten around to changing our offsite tape storage vendor, and the barcodes that the new vendor uses will be readable by the barcode reader in my library (previously, we had to use a cu
Author: George Sinclair - NOAA Federal <george.sinclair AT NOAA DOT GOV>
Date: Thu, 12 Sep 2013 16:14:10 -0400
On 2013-09-12 05:22, bingo wrote: I do not know any other easy fix but a true separation of executables and application data to be stored on different volumes. In general this is best practice anyway
Author: FAIDHERBE Thierry <thierry.faidherbe AT FOREM DOT BE>
Date: Fri, 13 Sep 2013 06:21:38 +0000
You can also try to start nsrexecd in debug, to see where it fails Log as local admin and launch nsrexecd -D 9 from %install_dir%\bin HTH TH Kind regards - Bien cordialement - Vriendelijke groeten, T
Author: Tony Albers <Tony.Albers AT PROACT DOT DK>
Date: Fri, 13 Sep 2013 07:03:57 +0000
Hi Michael, AFAIK you can't choose to only label "some" tapes in the library when using auto-labeling. If some of the barcodes are unreadable, you will run into errors. What you could do, is partitio
I wouldn't expect problems with the old tapes even if you turn on "Match barcodes". Not as long as you don't try to relabel/recycle them. This as the setting is applied during the labeling process. B
Author: bingo <networker-forum AT BACKUPCENTRAL DOT COM>
Date: Fri, 13 Sep 2013 03:44:09 -0700
I think it is pretty simple: If you exclusively store the data you want to protect on specific volumes you just need to define them in the save set list. It avoids complicated directives and new dire
Author: Frank Swasey <Frank.Swasey AT UVM DOT EDU>
Date: Fri, 13 Sep 2013 08:06:57 -0400
I wouldn't expect problems with the old tapes even if you turn on "Match barcodes". Not as long as you don't try to relabel/recycle them. This as the setting is applied during the labeling process.
Author: Michael Leone <Michael.Leone AT PHA.PHILA DOT GOV>
Date: Fri, 13 Sep 2013 08:28:19 -0400
Yeah, I didn't think so. Ratz. I have 4500+ tapes I would need to do that to, and a legal restriction forbidding overwriting removable media, which means I would need to purchase 4500 new tapes, jus
Author: Michael Leone <Michael.Leone AT PHA.PHILA DOT GOV>
Date: Fri, 13 Sep 2013 08:30:57 -0400
I'm not so worried about the relabel/recycle aspect (at this time). I'm more worried about tapes not inventorying, or mounting correctly for recovers. And I'm still running jobs at the moment, so I
Author: FAIDHERBE Thierry <thierry.faidherbe AT FOREM DOT BE>
Date: Fri, 13 Sep 2013 13:14:43 +0000
? Networker uses volume name, not barcode values ! So it should not be a problem. So, what are your worries/problems about ? Th --Message d'origine-- De : EMC NetWorker discussion [mailto:NETWORKER
Author: Michael Leone <Michael.Leone AT PHA.PHILA DOT GOV>
Date: Fri, 13 Sep 2013 09:33:01 -0400
I was worried that if I inventoried a slot, and the actual tape label did not match the barcode label, then the tape wouldn't mount. But that should only be a problem on relabeling tapes (which at t
Author: FAIDHERBE Thierry <thierry.faidherbe AT FOREM DOT BE>
Date: Fri, 13 Sep 2013 14:11:44 +0000
It would not be a problem even if volume does not match barcode. Have a try : load barcode ABC001 on a volume, label it. In media db, volume label=ABC001, BARCODE=ABC001. Now, change barcode ABC001 t
Author: "Stanley R. Horwitz" <stan AT TEMPLE DOT EDU>
Date: Fri, 13 Sep 2013 15:23:02 +0000
Hello NetWorker list subscribers, For those of you who dont know, I run this list and I have been doing so for roughly the past 20 years. I am writing now because of two changes I feel need to be mad
Author: "Clark, Patricia A." <clarkpa AT ORNL DOT GOV>
Date: Fri, 13 Sep 2013 14:34:07 -0400
I guess change is inevitable. However it settles, this will still be the best list on Networker questions. The suggested name seems a bit cryptic. I know it's long, perhaps EMC-DataProtection-L? I al
Author: Michael Leone <Michael.Leone AT PHA.PHILA DOT GOV>
Date: Fri, 13 Sep 2013 15:17:44 -0400
I'm going to be out on leave all next week, and have already set my mail OoO notification. But I can't find the list URL to suspend myself for a week, so bounces don't happen. Anyone point me to that