Re: [nv-l] Propagating Node status on TRAPS
2006-05-09 08:39:28
Hi Leslie,
I found this in the "netmon.conf"
file
# Set to TRUE to ignore Link Up/Link
Down traps
NV_NETMON_IGNORE_LINK_UPDN=FALSE
The second line was remarked i removed
the remark, did start/stop netmon , but yet i dont see the change on IP
MAP for the specific interface!
Regards,
Usman Taokeer
Si3.
Leslie Clark <lclark AT us.ibm DOT com>
Sent by: owner-nv-l AT lists.us.ibm DOT com
09-05-06 04:34 PM
Please respond to
nv-l AT lists.us.ibm DOT com |
|
To
| nv-l AT lists.us.ibm DOT com
|
cc
|
|
Subject
| Re: [nv-l] Propagating Node status on
TRAPS |
|
Check in /usr/ov/conf/netmon.conf. On Unix, there is an option in there
that controls whether or not Netview will respond to generic traps by immediately
checking the current status. Perhaps that's where it is controlled on Windows
as well.
And no, no mibs are required for this.
Cordially,
Leslie A. Clark
IT Services Specialist, Network Mgmt
Information Technology Services Americas
IBM Global Services
(248) 552-4968 Voicemail, Fax, Pager
usman.taokeer AT s-iii DOT com
Sent by: owner-nv-l AT lists.us.ibm DOT com
05/09/2006 04:30 AM
Please respond to
nv-l AT lists.us.ibm DOT com |
|
To
| nv-l AT lists.us.ibm DOT com
|
cc
| fatih.celen AT impetus DOT ae, Nooruddin_Abbas_Ali/PS/TDS/Si3 AT s-iii DOT com,
nv-l AT lists.us.ibm DOT com, owner-nv-l AT lists.us.ibm DOT com
|
Subject
| Re: [nv-l] Propagating Node status on
TRAPS |
|
Just to add to it, do we need to load any specific MIBs to get that functionality?
usman.taokeer AT s-iii DOT com
Sent by: owner-nv-l AT lists.us.ibm DOT com
08-05-06 02:08 PM
Please respond to
nv-l AT lists.us.ibm DOT com |
|
To
| nv-l AT lists.us.ibm DOT com
|
cc
| fatih.celen AT impetus DOT ae, Nooruddin_Abbas_Ali/PS/TDS/Si3 AT s-iii DOT com
|
Subject
| [nv-l] Propagating Node status on TRAPS |
|
Hi List,
NV 7.1.4 FP04
Windows 2003 SP1
We have a Cisco router configured to forward traps to Netview server whenever
the Serial Link goes down! . The Netview is receiving traps successfully
but on the IP MAP the Interface status does not reflect the TRAP
i.e When a 'link down' trap is received on Netview the Interface status
stays 'GREEN'. It is only updated on the scheduled SNMP Poll. What else
needs to be done on the Netview part to make it reflect the change on the
'IP MAP' level!
Regards,
Usman Taokeer
Si3
|
|
|