Meyos,
All of this can be done with a smartset. If you use Cisco as
an example, the basic breakdown of their devices is:
Cisco =
1.3.6.1.4.1.9
routers =
1.3.6.1.4.1.9.1
switches =
1.3.6.1.4.1.9.5
Because of acquisitions, there are other OIDs
that belong to them, but you can expand this example to include whatever you
want
Question 1
- Make a smartset who's membership rule is sysObjectId = <your
desired targets OID>
Question 2 -
Make a ruleset that blocks all events except those coming from members of your
smartset in #1. Then when you open your event window, create a dynamic
workspace that uses this ruleset. Or use this ruleset as the default for
the event window itself. Jane's last message told you how to save those
for your customer.
Question 3 -
The sysObjectId and the EnterpriseId are related but different. If you
look at my Cisco example, the OID that stops at 4.1.9 is the Enterprise Id, and
as you can see, they add subsets to it by adding additional numbers, 4.1.9.1 for
routers, 4.1.9.5 for switches. Then they add additional numbers to each of
these to identify specific router and switch types. For examples look in
/usr/OV/conf/C/oid_to_sym file
Here are some
examples. These are sysObjectIds.
1.3.6.1.4.1.9.1.122:Cisco
Router:cisco-Rtr3620Family 1.3.6.1.4.1.9.1.123:Cisco
Router:CPA3600 # cpa3620 1.3.6.1.4.1.9.1.124:Cisco
Router:CPA3600 # cpa3640 1.3.6.1.4.1.9.1.125:Cisco
Router:cisco-C7200 1.3.6.1.4.1.9.1.126:Cisco
Router:cisco-Rtr700Family 1.3.6.1.4.1.9.1.127:Cisco
Router:cisco-Rtr700Family 1.3.6.1.4.1.9.1.128:Cisco
Router:cisco-Rtr700Family
Question 4 - Just make your smartset stop at the Enterprise
id. If a vendor uses more then 1 Enterprise id, just include all of them
in the qualifying rule for the smartset. Again in the case of Cisco, you
would just say
"anything whose sysObjectId included 1.3.6.1.4.1.9 AND
<Any Other sysObjectId They Own>"
Hope this helps, Good
luck!
Bill
Bill Stringfellow EDS - Bank of America Account
Team Network Management Support CA4-704-02-03 2000 Clayton Road,
Building D Concord, CA 94520
Office:
925.692.7283 Fax:
925.675.1763 Email:
william.stringfellow AT eds DOT com Cell:
925.765.2648
Thanks Jane,
I am having a problem about the event matching configuration.
1- I want to create a workspace for a specific device type with
sysObjectID = 1.3.6.1.4.1.xx.yy.zz for example
2- I want All events (Treshold, Node UP, Node Down, etc ..) and All Traps
from that Device type to be displayed on that Workspace
3- What Attributes represents the sysObjectID? is it the
EntrepriseID?
4- What about when you want to display events from all Devices from
the same vendor, can youu use "Greater or equal to" selection?
5- Any suggestions
6- any *.rs file sample would help.
Thank
You, Meyos "ALLEZ LES LIONS INDOMPTABLES"
Post your free ad now! Yahoo!
Canada Personals
|