nv-l

Re: Event Console Trouble

1998-08-20 07:14:24
Subject: Re: Event Console Trouble
From: Tim Clark <Tim.Clark AT TAVVE DOT COM>
To: nv-l AT lists.tivoli DOT com
Date: Thu, 20 Aug 1998 07:14:24 -0400
Event management, bundled solution
http://www.tavve.com/brochure/eventwatch.html


-----Original Message-----
From: Cristina Zabeu <czabeu AT dev.tivoli DOT com>
To: NV-L AT UCSBVM.UCSB DOT EDU <NV-L AT UCSBVM.UCSB DOT EDU>
Date: Monday, August 17, 1998 1:21 PM
Subject: Re: Event Console Trouble


>Regarding the Event Console Trouble problem posted lately here...
>
>The answers from Vladimir and Bryan were accurate. I'd like just to add
>another hint, which is that basically, when you create a ruleset to
>receive NetView events,
>the nvserverd.baroc file MUST BE LOADED AFTER tecad_ov.baroc when
>creating the initial rulebase.
>If not, very unpredictable things can happen.
>
>The way to verify this is to check
>$BINDIR/TME/TEC/<name of ruleset directory>/TEC_CLASSES/.load_classes
>This file lists all the baroc files in the rulebase in order.
>
>If nvserverd.baroc is before tecad_ov.baroc you might see something like
>this in your trace files:
>
>>From /tmp/tec_master
>Jun 22 08:53:58 tec_master[27471] ERR tec_exit_msg.c:247: Process T/EC
>Rule exits with exit code 211: Process terminated...
>Jun 22 08:53:58 tec_master[27471] ERR tec_exit_msg.c:247: Process TEC
>Master exits with exit code 43: Child process died...
>Jun 22 08:53:59 tec_master[27Jun 22 08:54:00 tec_dispatch[27477] ERR
>tec_disp_msg.c:139: T/EC Dispatch terminates with error 67
>Jun 22 08:54:00 tec_dispatch[27477] ERR tec_exit_msg.c:247: Process T/EC
>Dispatch exits with exit code 40: Lost communic...
>
>>From /tmp/tec_dispatch
>Jun 22 08:54:00 tec_dispatch[27477] ERR tec_disp_msg.c:139: T/EC
>Dispatch terminates with error 67
>Jun 22 08:54:00 tec_dispatch[27477] ERR tec_exit_msg.c:247: Process T/EC
>Dispatch exits with exit code 40: Lost communic...
>Jun 22 08:54:00 tec_dispatch[27477] ERR tec_ipc_accept.c:145: ipc_accept
>failed (error 67)
>
>The TEC team is aware of this and appropriate documentation should be in
>place for NetView 5.1. Meanwhile, remember to check this also when
>forwarding your events from NetView to TEC.
>
>Hope this helps,
>Cristina Zabeu

<Prev in Thread] Current Thread [Next in Thread>