Why would you do that?! Are you trying to see how many errors you can cause
by using non-sense combinations? Either
ALL_LOCAL_DRIVES and exclude C: \
or
specify D: only in the file section.
You are including the D:\ drive which should be included when you said
ALL_LOCAL_DRIVES.
Regards,
Patrick Whelan
VERITAS Certified NetBackup Support Engineer for UNIX.
VERITAS Certified NetBackup Support Engineer for Windows.
netbackup AT whelan-consulting.co DOT uk
-----Original Message-----
From: veritas-bu-bounces AT mailman.eng.auburn DOT edu
[mailto:veritas-bu-bounces AT mailman.eng.auburn DOT edu] On Behalf Of Justin
Piszcz
Sent: 29 April 2011 18:22
To: veritas-bu AT mailman.eng.auburn DOT edu
Subject: [Veritas-bu] Error 90 on Windows hosts with NBU 7.x client for
Windows?
Hello,
Has anyone seen this?
Windows 2008 clients:
CLIENT:
ALL_LOCAL_DRIVES
On the client,
EXCLUDE C:\
INCLUDE D:\
For the C:\ backup it will get the following error:
Apr 29, 2011 10:09:22 AM - mounting TAPE01 Apr 29, 2011 10:09:24 AM -
connecting Apr 29, 2011 10:09:24 AM - connected; connect time: 0:00:00 Apr
29, 2011 10:09:59 AM - mounted TAPE01; mount time: 0:00:37 Apr 29, 2011
10:09:59 AM - positioning TAPE01 to file 59 Apr 29, 2011 10:10:31 AM -
positioned TAPE01; position time: 0:00:32 Apr 29, 2011 10:10:31 AM - begin
writing Apr 29, 2011 10:11:31 AM - end writing; write time: 0:01:00 media
manager received no data for backup image (90)
With < 7.0 this never happened, is this a bug?
The data in D:\ does get backed up however.
Justin.
_______________________________________________
Veritas-bu maillist - Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
_______________________________________________
Veritas-bu maillist - Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
|