Firewall? Try to telnet <hostname> vnetd from the client to the Master and Media servers.

You can also try using this command:
bptestbpcd -client <clientname> -debug
Run this from Master and Media servers. Debug gives you the most output and isn't documented, -verbose gives you a little less output, and no switch gives you only a couple of lines.

Rusty Major, MCSE, BCFP, VCS ▪ Sr. Storage Engineer ▪ SunGard Availability Services ▪ 757 N. Eldridge Suite 200, Houston TX 77079 ▪ 281-584-4693
Keeping People and Information Connected® ▪ http://availability.sungard.com/
P Think before you print
CONFIDENTIALITY:  This e-mail (including any attachments) may contain confidential, proprietary and privileged information, and unauthorized disclosure or use is prohibited.  If you received this e-mail in error, please notify the sender and delete this e-mail from your system.


SACHIN ARORA <sachinar1 AT gmail DOT com>
Sent by: <veritas-bu-bounces AT mailman.eng.auburn DOT edu>

09/18/2010 10:24 AM

To
VERITAS-BU AT mailman.eng.auburn DOT edu
cc
Subject
Re: [Veritas-bu] Need help!





Hi,
 
nslookup work fine from/to all three servers on both name and IP address?
 
Regards
Sam

On Sat, Sep 18, 2010 at 10:27 AM, Patrick <netbackup AT whelan-consulting.co DOT uk> wrote:
Hi Sam,

 

What do you get if you do an nslookup from/to all three servers on both name and IP address?

 

Regards,

 

Patrick Whelan

VERITAS Certified NetBackup Support Engineer for UNIX.

VERITAS Certified NetBackup Support Engineer for Windows.

 

netbackup AT whelan-consulting.co DOT uk

 

cid:image001.gif@01C99E80.E2717A60

 

From: veritas-bu-bounces AT mailman.eng.auburn DOT edu [mailto:veritas-bu-bounces AT mailman.eng.auburn DOT edu] On Behalf Of SACHIN ARORA
Sent:
18 September 2010 3:20 PM


To:
VERITAS-BU AT mailman.eng.auburn DOT edu
Subject:
[Veritas-bu] Need help!

 

I have following configuration

 

Master server - Solaris 9 - NB6.5.4

 

Media server  - Solaris 9 - NB6.5.4

 

Client - Win2003 SP2 - NB6.5.4

 

Issue : Backup starts and goes to hung state without writing any data  :

 

Sep 18, 2010 6:39:12 AM - granted resource  X19351
Sep 18, 2010 6:39:12 AM - granted resource  L700_L6_LTO2_DRV018
Sep 18, 2010 6:39:12 AM - granted resource  USA0300UX2376_STK_L700_LIB6
Sep 18, 2010 6:39:12 AM - estimated 0 kbytes needed
Sep 18, 2010 6:39:14 AM - started process bpbrm (pid=29960)
Sep 18, 2010 6:39:16 AM - connecting
Sep 18, 2010 6:39:17 AM - connected; connect time: 0:00:00
Sep 18, 2010 6:39:23 AM - mounting X19351
Sep 18, 2010 6:39:58 AM - mounted X19351; mount time: 0:00:35
Sep 18, 2010 6:39:59 AM - positioning X19351 to file 1
Sep 18, 2010 6:40:01 AM - positioned X19351; position time: 0:00:02
Sep 18, 2010 6:40:01 AM - begin writing

 

- bpclntcmd - works fine - ip/hostname

- bptestbpcd works fine

- bpgetconfig -g works fine.

 

bpcd logs shows --->


07:19:52.250 [11196.11200] <2> bpcd valid_server: comparing usa0300ux2 and usa9040as3
07:19:52.250 [11196.11200] <2> hosts_equal: gethostbyname failed for usa0300ux2 : The requested name is valid, but no data of the r (0)
07:19:52.250 [11196.11200] <2> bpcd valid_server: comparing usa0300ux2 and usa9040as3
07:19:52.250 [11196.11200] <4> bpcd valid_server: usa9040as3 is not a master server
07:19:52.250 [11196.11200] <16> bpcd valid_server: usa9040as3 is not a media server either

07:19:52.250 [11196.11200] <2> bpcd main: output socket port number = 1
07:19:52.250 [11196.11200] <2> bpcd main: Duplicated vnetd socket on stderr
07:19:52.250 [11196.11200] <2> bpcd main: <---- NetBackup 6.5 0 ------------initiated
07:19:52.250 [11196.11200] <2> bpcd main: VERBOSE = 0
07:19:52.250 [11196.11200] <2> bpcd exit_bpcd: exit status 46  ----------->exiting
07:19:52.250 [11196.11200] <4> bpcd exit_bpcd: FTL - BPCD EXIT STATUS 46

07:19:52.250 [11196.11200] <16> bpcd main: Server access denied
07:19:52.343 [11228.11232] <2> bpcd main: offset to GMT 18000
07:19:52.343 [11228.11232] <2> bpcd main: Got socket for input 512
07:19:52.343 [11228.11232] <2> logconnections: BPCD ACCEPT FROM 13.129.26.50.4972 TO 13.129.26.50.13724
07:19:52.343 [11228.11232] <2> bpcd main: setup_sockopts complete

 

 

 Kindly help me to fix the issue.

 

Regards

Sam


 

_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
<Prev in Thread] Current Thread [Next in Thread>