Veritas-bu

Re: [Veritas-bu] bperror differences in 6.5.x and 7.0

2010-07-29 17:04:47
Subject: Re: [Veritas-bu] bperror differences in 6.5.x and 7.0
From: <Rusty.Major AT sungard DOT com>
To: "Green, Steven" <steven.green AT teldta DOT com>
Date: Thu, 29 Jul 2010 16:04:14 -0500

I can confirm the same command worked for me in a NBU 7.0 environment on Solaris 10 Master. I also checked the same command on a Windows 7.0 media server and it worked as well.

Rusty Major, MCSE, BCFP, VCS ▪ Sr. Storage Engineer ▪ SunGard Availability Services ▪ 757 N. Eldridge Suite 200, Houston TX 77079 ▪ 281-584-4693
Keeping People and Information Connected® ▪ http://availability.sungard.com/
P Think before you print
CONFIDENTIALITY:  This e-mail (including any attachments) may contain confidential, proprietary and privileged information, and unauthorized disclosure or use is prohibited.  If you received this e-mail in error, please notify the sender and delete this e-mail from your system.


"Green, Steven" <steven.green AT teldta DOT com>
Sent by: <veritas-bu-bounces AT mailman.eng.auburn DOT edu>

07/29/2010 11:10 AM

To
"'VERITAS-BU AT MAILMAN.ENG.AUBURN DOT EDU'" <VERITAS-BU AT MAILMAN.ENG.AUBURN DOT EDU>
cc
Subject
Re: [Veritas-bu] bperror differences in 6.5.x and 7.0





We are currently doing testing with Netbackup 7.0 (currently on 6.5.4) and when I tested the command it worked fine. We are on a Solaris master server, if that makes any difference.
 
[thylacine:root]: bperror -U -backstat -hoursago 96 -by_statcode
 0   the requested operation was successfully completed
        dcmx001.devc.tds.test miwisu87.corp.tds.local
        miwisu88.corp.tds.local miwitestsu17.corp.tds.local
        miwitestsu18.corp.tds.local miwitestsu19.corp.tds.local
 1   the requested operation was partially successful
        miwitestsu19.corp.tds.local
57   client connection refused
        miwitestsu18.corp.tds.local

Steve Green



From: Scott Jacobson [mailto:SJACOBSO AT novell DOT com]
Sent:
Wednesday, July 28, 2010 2:11 PM
To:
Douglas Preston; VERITAS-BU AT MAILMAN.ENG.AUBURN DOT EDU
Subject:
Re: [Veritas-bu] bperror differences in 6.5.x and 7.0

I'd also be interested in a resolution to this as we use the output to populate an SQL DB - thanks.

>>> "Preston, Douglas" <dlpreston AT lereta DOT com> 7/28/2010 9:00 AM >>>
In 6.5.x bperror -U -backstat -hoursago 24 -by_statcode
Gave a condensed output of all clients backed up in the last 24 hours sorted by status code

Example
 0   the requested operation was successfully completed
        svcacibu1 scacibu01
 1   the requested operation was partially successful
        scacibu02
 2   none of the requested files were backed up
        scacibu04
52   timed out waiting for media manager to mount volume
        svcacibu1
58   can't connect to client
        scacibu03

Now under 7.0 bperror -U -backstat -hoursago 24 -by_statcode
Only gives the master server in the output
Example

 0   the requested operation was successfully completed
        svcacibu1

Does anyone have any clue as to why this would be, the bperror -h indicates the command should still produce the output that 6.5.x produced.


Doug Preston
_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu

http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu