Veritas-bu

Re: [Veritas-bu] mixing LTO2 and LTO4

2010-03-03 10:41:20
Subject: Re: [Veritas-bu] mixing LTO2 and LTO4
From: "smpt" <smpt1 AT peppas DOT gr>
To: "'Grigore Petrisor'" <edy25ro AT yahoo DOT com>, <VERITAS-BU AT mailman.eng.auburn DOT edu>
Date: Wed, 3 Mar 2010 17:40:24 +0200

You can do it.

Use HCART2 drive and media type for LTO2 and HCART for LTO4. Configured the appropriate barcode rules and you are ok.

This may be helpful

http://seer.entsupport.symantec.com/docs/336024.htm

 

 

From: veritas-bu-bounces AT mailman.eng.auburn DOT edu [mailto:veritas-bu-bounces AT mailman.eng.auburn DOT edu] On Behalf Of Grigore Petrisor
Sent: Wednesday, March 03, 2010 3:19 PM
To: VERITAS-BU AT mailman.eng.auburn DOT edu
Subject: [Veritas-bu] mixing LTO2 and LTO4

 

Hi

I want to know if there is a possibility to mix LTO2 and LTO4 drives and media in the same library StorageTek SL500 

with Netbackup 5.1.

If there is documentation for this ... pls i want to know

TY

 

_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu