Veritas-bu

Re: [Veritas-bu] Backing up cluster after failover

2009-06-15 02:20:56
Subject: Re: [Veritas-bu] Backing up cluster after failover
From: "WEAVER, Simon \(external\)" <simon.weaver AT astrium.eads DOT net>
To: <VERITAS-BU AT mailman.eng.auburn DOT edu>
Date: Mon, 15 Jun 2009 07:17:46 +0100
If the F: Drive is on the SAN, that is good! What seems to be the
problem is that the F: Drive can only be seen on one Node if you are
backing up the "Physical" Computer Name.

So lets say you have this:

SERVER1
SERVER2

The F: Drive is on Server 2. If you do the ALL LOCAL DRIVES on SERVER1
and SERVER2, then you will get a STATUS 71 on SERVER1, because the F:
Drive is not present.

In order to backup the F: Drive, you would need a Backup Policy to be
configured for the CLUSTER VIRTUAL NAME.

Do you know what this name is ?

Simon 

-----Original Message-----
From: veritas-bu-bounces AT mailman.eng.auburn DOT edu
[mailto:veritas-bu-bounces AT mailman.eng.auburn DOT edu] On Behalf Of
smwoodcrafts
Sent: Friday, June 12, 2009 7:31 PM
To: VERITAS-BU AT mailman.eng.auburn DOT edu
Subject: [Veritas-bu] Backing up cluster after failover


I just checked with the owner. Everything is in the same cluster group.
I did find out that F: resides on our SAN. It's not physically in one of
the servers. Ownership changes with a failover the the newly active
node.

Any more ideas?

It's clear I'm not understanding this.

+----------------------------------------------------------------------
|This was sent by dseymour AT ap DOT org via Backup Central.
|Forward SPAM to abuse AT backupcentral DOT com.
+----------------------------------------------------------------------


_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

This email (including any attachments) may contain confidential
and/or privileged information or information otherwise protected
from disclosure. If you are not the intended recipient, please
notify the sender immediately, do not copy this message or any
attachments and do not use it for any purpose or disclose its
content to any person, but delete this message and any attachments
from your system. Astrium disclaims any and all liability if this
email transmission was virus corrupted, altered or falsified.
-o-
Astrium Limited, Registered in England and Wales No. 2449259
Registered Office:
Gunnels Wood Road, Stevenage, Hertfordshire, SG1 2AS, England
_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu