Re: [Veritas-bu] NBU 5.1 Migration from Win to HP-UX
2009-05-06 14:37:39
.On Wed, May 6, 2009 at 12:55 PM, David McMullin <David.McMullin AT cbc-companies DOT com> wrote:
Regarding moving master server OS:
1. Install the new server OS and NetBackup
2. Stop NetBackup on old environment
3. Cold Catalog Backup
4. Rename old master and new master - so new master has old name
5. Start NetBackup on new master
6. Catalog Restore from Cold Catalog Backup Absolutely NOT. This cross-platform (Windows to Unix) migration WILL NOT WORK. You will have end-of-line termination issues and NetBackup is unlikely to even start up.
.../Ed
Ed Wilts, RHCE, BCFP, BCSD, SCSP, SCSE
ewilts AT ewilts DOT org