Re: [Veritas-bu] STK SL3000 - NBU 6.5.3
2009-03-11 11:24:03
David,
I saw this in a posting a few months back...since we resell the STK line I hung
onto it in case I ever needed it....it may or may not resolve your issue...let
us know:
Symptoms
Users of NetBackUp version 6.x cannot configure a new SL3000 tape library.
When installing a new SL3000 tape library, users of Symantics Veritas NetBackUp
cannot configure the library.
Resolution
Configuring NetBackUp to work with SL3000 requires a package update
When installing an SL3000 with Veritas NetBackUp 6.0 or 6.5. And the library
is connected via Fibre Channel, NetBackUp will fail to configure the library
properly.
Netbackup doesn't contain the SL3000 library mappings.
The fix is provide by Symantic for the Veritas NetBackUp products in the form
of a package update.
The
following link will provide the package update for download, package install
instructions and other package details.
http://seer.entsupport.symantec.com/docs/302598.htm
Note: the link provided is outside Sun Microsystem control and could be
deleted, changed or moved without the knowledge of Sun. Contact Symantics for
problems, information or support concerning the referenced package.
Symantic Document ID: 302598
Renee
-----Original Message-----
From: veritas-bu-bounces AT mailman.eng.auburn DOT edu
[mailto:veritas-bu-bounces AT mailman.eng.auburn DOT edu] On Behalf Of Clooney,
David
Sent: Wednesday, March 11, 2009 9:31 AM
To: VERITAS-BU AT mailman.eng.auburn DOT edu
Subject: [Veritas-bu] STK SL3000 - NBU 6.5.3
Hi All
Hit another snag in a new deployment, seem to be requiring knowledge
from the group on a number of occasions over the last couple of months,
its appreciated.
Our DR environment has just acquired an STK SL3000 and we are having
issues with the robotic config in NBU.
If you run the wizard the results are that NBU interprets the library as
remote for some unknown reason.
We have downloaded the device mappings and applied successfully however
don't seem to be able to get it working.
The T10kB drives in the library are fine.
The library and drives are dual pathed and visible down both paths
c5::500104f000ad41c8,0 med-changer connected configured
unknown
c5::500104f000ad41d8,0 tape connected configured
unknown
c5::500104f000ad41e1,0 tape connected configured
unknown
c5::500104f000ad41e4,0 tape connected configured
unknown
c5::500104f000ad41ed,0 tape connected configured
unknown
c6 fc connected unconfigured
unknown
c7 fc-fabric connected configured
unknown
c7::500104f000ad41c8,0 med-changer connected configured
unknown
c7::500104f000ad41d8,0 tape connected configured
unknown
c7::500104f000ad41e1,0 tape connected configured
unknown
c7::500104f000ad41e4,0 tape connected configured
unknown
c7::500104f000ad41ed,0 tape connected configured
unknown
additionally scan -chnager finds the library and robot no problem
************************************************************
*********************** SDT_CHANGER ************************
************************************************************
------------------------------------------------------------
Device Name : "/dev/sg/c0tw500104f000ad41c8l0"
Passthru Name: "/dev/sg/c0tw500104f000ad41c8l0"
Volume Header: ""
Port: -1; Bus: -1; Target: -1; LUN: -1
Inquiry : "STK SL3000 2.05"
Vendor ID : "STK "
Product ID : "SL3000 "
Product Rev: "2.05"
Serial Number: "571000200222"
WWN : ""
WWN Id Type : 0
Device Identifier: ""
Device Type : SDT_CHANGER
NetBackup Robot Type: 8
Removable : Yes
Device Supports: SCSI-5
Number of Drives : 4
Number of Slots : 200
Number of Media Access Ports: 26
Drive 1 Serial Number : "572004000580"
Drive 2 Serial Number : "572004000573"
Drive 3 Serial Number : "572004000561"
Drive 4 Serial Number : "572004000267"
Flags : 0x0
Reason: 0x0
------------------------------------------------------------
Device Name : "/dev/sg/c1tw500104f000ad41c8l0"
Passthru Name: "/dev/sg/c1tw500104f000ad41c8l0"
Volume Header: ""
Port: -1; Bus: -1; Target: -1; LUN: -1
Inquiry : "STK SL3000 2.05"
Vendor ID : "STK "
Product ID : "SL3000 "
Product Rev: "2.05"
Serial Number: "571000200222"
WWN : ""
WWN Id Type : 0
Device Identifier: ""
Device Type : SDT_CHANGER
NetBackup Robot Type: 8
Removable : Yes
Device Supports: SCSI-5
Number of Drives : 4
Number of Slots : 200
Number of Media Access Ports: 26
Drive 1 Serial Number : "572004000580"
Drive 2 Serial Number : "572004000573"
Drive 3 Serial Number : "572004000561"
Drive 4 Serial Number : "572004000267"
Flags : 0x0
Reason: 0x0
However, even I I try add the library through tpconfig I just don't seem
to be able to get is working.
Anyone know of any gotach'a with this particular library??
Regards
David Clooney
Enterprise Storage Services
Notice to recipient:
The information in this internet e-mail and any attachments is confidential and
may be privileged. It is intended solely for the addressee. If you are not the
intended addressee please notify the sender immediately by telephone. If you
are not the intended recipient, any disclosure, copying, distribution or any
action taken or omitted to be taken in reliance on it, is prohibited and may be
unlawful.
When addressed to external clients any opinions or advice contained in this
internet e-mail are subject to the terms and conditions expressed in any
applicable governing terms of business or client engagement letter issued by
the pertinent Bank of America group entity.
If this email originates from the U.K. please note that Bank of America, N.A.,
London Branch and Banc of America Securities Limited are authorised and
regulated by the Financial Services Authority. For all U.K. corporate
disclosures, please refer to www.bankofamerica.com/ukcompanies
_______________________________________________
Veritas-bu maillist - Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
_______________________________________________
Veritas-bu maillist - Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
|
|
|