Veritas-bu

Re: [Veritas-bu] install 6.0 MP5 breaks vltopmenu

2008-02-08 09:16:26
Subject: Re: [Veritas-bu] install 6.0 MP5 breaks vltopmenu
From: "Stump, Bob A" <Bob.A.Stump AT fnis DOT com>
To: <veritas-bu AT mailman.eng.auburn DOT edu>
Date: Fri, 8 Feb 2008 07:59:13 -0600

Doh!

Never mind.

I just found the MP5 vault patch. J

 

“How many people in how many countries does this go out to?”

he asked while wiping this morning’s egg of his face.

 

 

 


From: veritas-bu-bounces AT mailman.eng.auburn DOT edu [mailto:veritas-bu-bounces AT mailman.eng.auburn DOT edu] On Behalf Of Stump, Bob A
Sent: Friday, February 08, 2008 8:31 AM
To: veritas-bu AT mailman.eng.auburn DOT edu
Subject: [Veritas-bu] install 6.0 MP5 breaks vltopmenu

 

After upgrading from 6.0 MP4 to 6.0 MP5 on AIX 3 5 master the vltopmenu fails to load.

I’m sure I’m not the only one who has encountered this problem.

Has anyone reading this listing experienced this error?

 

# vltopmenu

Could not load program vltopmenu:

rtld: 0712-001 Symbol MachineFetch__Q3_7Veritas3EMM41_TAO_MachineResultSet_1_Rem                                      ote_Proxy_ImplFP12CORBA_ObjectPCcUiN23Q3_7Veritas3EMM22Machine_Record_Seq_out wa                                      s referenced

      from module vltopmenu(), but a runtime definition

            of the symbol was not found.

rtld: 0712-001 Symbol MachineFetch__Q3_7Veritas3EMM18MachineResultSet_1FPCcUiN22                                      Q3_7Veritas3EMM22Machine_Record_Seq_out was referenced

      from module vltopmenu(), but a runtime definition

            of the symbol was not found.

rtld: 0712-001 Symbol __ct__65TAO_ClientRequestInfo_Veritas_EMM_MachineResultSet                                      _1_MachineFetchFP19TAO_GIOP_InvocationP12CORBA_ObjectPCcRCUiRCUiRCUi was referen                                      ced

      from module vltopmenu(), but a runtime definition

            of the symbol was not found.

rtld: 0712-001 Symbol ovgetlocale was referenced

      from module vltopmenu(), but a runtime definition

            of the symbol was not found.

______________

The information contained in this message is proprietary and/or confidential. If you are not the
intended recipient, please: (i) delete the message and all copies; (ii) do not disclose,
distribute or use the message in any manner; and (iii) notify the sender immediately. In addition,
please be aware that any message addressed to our domain is subject to archiving and review by
persons other than the intended recipient. Thank you.
_____________

______________

The information contained in this message is proprietary and/or confidential. If you are not the
intended recipient, please: (i) delete the message and all copies; (ii) do not disclose,
distribute or use the message in any manner; and (iii) notify the sender immediately. In addition,
please be aware that any message addressed to our domain is subject to archiving and review by
persons other than the intended recipient. Thank you.
_____________
_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu