Veritas-bu

[Veritas-bu] Error code 233 premature eof encountered

2008-01-25 10:37:11
Subject: [Veritas-bu] Error code 233 premature eof encountered
From: ssloh AT singnet.com DOT sg
To: veritas-bu <veritas-bu AT mailman.eng.auburn DOT edu>
Date: Fri, 25 Jan 2008 23:11:21 +0800 (SGT)
Hi folk,

Anybody encountered problem below before.

Would like to check if the error message means that it has problem opening the 
catalog ?

00:14:40.582 [12683] <2> logconnections: BPDBM CONNECT FROM
10.84.14.41.36024 TO 10.84.14.41.13721
00:14:41.182 [12683] <2> get_long: (2) premature end of file (byte 1)
00:14:41.183 [12683] <2> db_getdata: get_string() failed: I/O error (5) 
premature end of file encountered (-9)
00:14:41.202 [12683] <2> db_end: no DONE from db_getreply(): premature eof 
encountered
00:14:41.203 [12683] <2> db_IMAGE: db_end() failed: premature eof encountered
00:14:41.206 [12683] <16> write_backup: cannot add fragment to image database, 
error = premature eof encountered
00:14:41.208 [12683] <2> send_brm_msg: EXIT clientname_1200327043 233

VNBU 4.5 error code 233:
Master Server (Media Server) : Solaris 8 VNBU version: 4.5GA Tape library: 
Sun L100 Tape drives: 5 x Seagate LTO1
- The size of data written on the backup that failed with error 233 varies 
among different clients. Some of them backup 10 GB then failed, some of them
only backup few MB then failed.
- The error 233 is not specific to particular clients nor particular media 
ID nor particular tape drive

The NBU catalog is stored in NFS from NetApps and it has been running for years 
without problem.
Currently the NBU catalog size is about 80GB

Any ideas or suggestion are strongly wellcome ???

Thanks 
_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu