Environment:
ATL P3000 (robot/drives) connected to a bridge
Bridge connected to switch-A
Switch-A connected to NeoScale device
Neo Scale connected to Switch-B
Switch-B connets to host HBA
NB Hardware
System Configuration: Sun Microsystems sun4u Sun Fire V890
System clock frequency: 150 MHz
Memory size: 32768 Megabytes
Problem:
The above NB master server is working fine. It can connect to the drives and the robot with no issues. What has changed is that we have built a new master server. This new master server has the same name as the original master server but a different ip address. New zones have been set up so that the new master server is zoned to see the P3000 and its tape drives, just like the original master server. Both masters are online until we can get the new master (sgscan) to see the changer. Once the new master is situated, we will then migrate from the existing master to the new master. The existing master will be decommissioned and shutdown.
When we run sg_build and sg_install, all is fine.....for the drives, but we continue to receive the following error for the robot
# /usr/sbin/luxadm -e create_fabric_device -f >>/etc/cfg/fp/fabric_WWN_map
ID[luxadm.create_fabric_device.2316] configuration failed for line (/devices/pci@9,600000/SUNW,emlxs@2/fp@0,0:fc::210100e08baad429) in file: /etc/cfg/fp/fabric_WWN_map. I/O error
when we run sgscan, sgscan see's the tape devices but does not see the changer (The above message is also produced in the /var/adm/messages log when we initiate sg_install
Any and all help is appreciated
Thanks
Gary
|