Veritas-bu

Re: [Veritas-bu] NBU Device Manager Wont Start

2007-08-30 09:02:58
Subject: Re: [Veritas-bu] NBU Device Manager Wont Start
From: "WEAVER, Simon (external)" <simon.weaver AT astrium.eads DOT net>
To: "'Preston, Douglas L'" <dpreston AT landam DOT com>, veritas-bu AT mailman.eng.auburn DOT edu
Date: Thu, 30 Aug 2007 13:44:57 +0100
Tried that - wont kill it !! I found a file thanks to another member, which
I will try soon ....

I know of and use the pstools on a daily basis. This one process wont die !

Regards

Simon Weaver
3rd Line Technical Support
Windows Domain Administrator 

EADS Astrium Limited, B23AA IM (DCS)
Anchorage Road, Portsmouth, PO3 5PU

Email: Simon.Weaver AT Astrium.eads DOT net



-----Original Message-----
From: Preston, Douglas L [mailto:dpreston AT LANDAM DOT com] 
Sent: Thursday, August 30, 2007 1:39 PM
To: WEAVER, Simon (external); veritas-bu AT mailman.eng.auburn DOT edu
Subject: RE: [Veritas-bu] NBU Device Manager Wont Start


On wilndows I use a dos utility set called pstools.  It allows killing 99%
of tasks that are unkillable.  It also has a few other utils that I use once
in a while but the main one I use is the pskill util.  It can kill on local
machine and remote machhines as long as they are windows machines.

http://www.microsoft.com/technet/sysinternals/Utilities/PsTools.mspx

Doug Preston
Systems Engineer
Land America Tax and Flood Services
Phone 626-339-5221 Ext 1104
Email  dlpreston AT landam DOT com


------------------------------------------------------------------------
------------
NOTICE: This electronic mail transmission may constitute a communication
that is legally privileged. It is not intended for transmission to, or
receipt by, any unauthorized persons. If you have received this electronic
mail transmission in error, please delete it from your system without
copying it, and notify the sender by reply e-mail, so that our address
record can be corrected.
------------------------------------------------------------------------
------------




-----Original Message-----
From: veritas-bu-bounces AT mailman.eng.auburn DOT edu
[mailto:veritas-bu-bounces AT mailman.eng.auburn DOT edu] On Behalf Of WEAVER,
Simon (external)
Sent: Wednesday, August 29, 2007 11:03 PM
To: 'veritas-bu AT mailman.eng.auburn DOT edu'
Subject: [Veritas-bu] NBU Device Manager Wont Start


All
A Robotic Library was rebooted, which is shared with a Master and 10 Media
Servers. Master Server (Win2k3 NBU 5.1 MP4) was also rebooted

Although all Media Servers are online, one server and its service (device
manager) refuses to start stating in the logs "Another ltid daemon is
already running"

Cannot find anything on the web that references this for Windows. 

I recall in the old days of 3.4, you could KILL processes within the NBU
Admin Console. Cannot seem to do this in 5.1, but I do see them listed.

I have rebooted the server, used task manager and it will not die !!

Any ideas?
Thanks

Regards

Simon Weaver
3rd Line Technical Support
Windows Domain Administrator 

EADS Astrium Limited, B23AA IM (DCS)
Anchorage Road, Portsmouth, PO3 5PU

Email: Simon.Weaver AT Astrium.eads DOT net <mailto:Simon.Weaver AT 
Astrium.eads DOT net> 



This email (including any attachments) may contain confidential and/or
privileged information or information otherwise protected from disclosure.
If you are not the intended recipient, please notify the sender immediately,
do not copy this message or any attachments and do not use it for any
purpose or disclose its content to any person, but delete this message and
any attachments from your system. Astrium disclaims any and all liability if
this email transmission was virus corrupted, altered or falsified.
---------------------------------------------------------------------
Astrium Limited, Registered in England and Wales No. 2449259 Registered
Office: Gunnels Wood Road, Stevenage, Hertfordshire, SG1 2AS, England
_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

This email (including any attachments) may contain confidential and/or 
privileged information or information otherwise protected from disclosure. If 
you are not the intended recipient, please notify the sender immediately, do 
not copy this message or any attachments and do not use it for any purpose or 
disclose its content to any person, but delete this message and any attachments 
from your system. Astrium disclaims any and all liability if this email 
transmission was virus corrupted, altered or falsified.
---------------------------------------------------------------------
Astrium Limited, Registered in England and Wales No. 2449259
Registered Office: Gunnels Wood Road, Stevenage, Hertfordshire, SG1 2AS, England
_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu