Veritas-bu

[Veritas-bu] Flash Backup Issue

2007-06-27 21:33:34
Subject: [Veritas-bu] Flash Backup Issue
From: "Jimenez, Daniel" <Daniel.Jimenez AT imb DOT com>
To: veritas-bu AT mailman.eng.auburn DOT edu
Date: Wed, 27 Jun 2007 17:59:06 -0700

Hey guys

 

I am having a problem backing up a drive that is mounted to one of our media servers. It is a flash backup setup on a Netbackup 6.0 (Windows 2003 Server Ent.). Not sure if I have forgotten some setting somewhere, any information would be appreciated.  Here is some information from the Activity Monitor and the Application Event Logs.

 

Detailed Status from Activity Monitor:

6/27/2007 3:55:04 PM - started process bpbrm (2720)

6/27/2007 3:55:04 PM - connecting

6/27/2007 3:55:05 PM - connected; connect time: 00:00:01

6/27/2007 3:55:09 PM - mounting T00959

6/27/2007 4:01:52 PM - Error bptm(pid=1732) ioctl (MTREW) failed on media id T00959, drive index 0, The I/O bus was reset. (1111) (bptm.c.7675)

6/27/2007 4:01:52 PM - mounted; mount time: 00:06:43

6/27/2007 4:01:54 PM - Error bptm(pid=1732) ioctl (MTREW) failed on media id T00959, drive index 0, The I/O bus was reset. (1111) (bptm.c.8954)

6/27/2007 4:01:56 PM - Error bpbrm(pid=2720) from client prxinfbkp105: ERR - bpbkar exiting because backup is aborting 

6/27/2007 4:02:00 PM - Error bpbrm(pid=2720) could not send server status message      

6/27/2007 4:01:54 PM - positioning T00959 to file 1

6/27/2007 4:02:06 PM - end writing

media position error(86)

 

-------------------

 

Application Event Log Info:

 

Source: NetBackup Tape Manag

Type: Error

Category: None

User: N/A

Event ID: 5122

 

Description:

DeviceloControl{} error on bus 0, target 0, lun 0: The request could not be performed because of an I/O device error.

 

 

 

Daniel Jimenez

 

_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
<Prev in Thread] Current Thread [Next in Thread>