Veritas-bu

[Veritas-bu] Help: New robot not taking old Tapes !

2006-12-25 01:22:44
Subject: [Veritas-bu] Help: New robot not taking old Tapes !
From: ayaz at mdsuae.ae (Ayaz Anjum)
Date: Mon, 25 Dec 2006 10:22:44 +0400
Hi Bobby !

 

Did u find any solution to following problem

 

Thanks

 

Ayaz

 

  _____  

From: Bobby Williams [mailto:bobbyrjw at bellsouth.net] 
Sent: Sunday, December 24, 2006 3:54 PM
To: 'Ayaz Anjum'; veritas-bu at mailman.eng.auburn.edu
Subject: RE: [Veritas-bu] Help: New robot not taking old Tapes !

 

When you removed the L100, it should have put all of the tapes in the NONE
status under robot.

 

If it didn't, you will have to move the media.

 

If it did, you should be able to inventory and it move the media for you.

 

Also, make sure that the 2 libraries read bar codes the same.

 

I had a ADIC i500 that read 8 characters.  When I moved the media to a
library that only read 6 characters, it said that the tapes were not the
same tape (cause of the bar code difference) and that they would have
duplicate names.

 

 

Bobby Williams 
2205 Peterson Drive 
Chattanooga, Tennessee  37421 
423-296-8200 

 

 

  _____  

From: veritas-bu-bounces at mailman.eng.auburn.edu
[mailto:veritas-bu-bounces at mailman.eng.auburn.edu] On Behalf Of Ayaz Anjum
Sent: Sunday, December 24, 2006 12:29 AM
To: veritas-bu at mailman.eng.auburn.edu
Subject: [Veritas-bu] Help: New robot not taking old Tapes !

HI Guys !

 

I have replaced L100 with L500 tape library on a veritas netbackup 6.0
environment.

 

Now I hv configured new L500 and when I am adding old media ( used with L100
with valid backups) its not allowing me to do, saying duplicate media and
error 37.

 

Any suggestions

 

Thanks

 

Ayaz

-------------- next part --------------
An HTML attachment was scrubbed...
URL: 
http://mailman.eng.auburn.edu/pipermail/veritas-bu/attachments/20061225/159ed626/attachment.html