Veritas-bu

[Veritas-bu] New Veritas installation - jobs do not start inparallel, all else queuing

2006-09-13 05:38:30
Subject: [Veritas-bu] New Veritas installation - jobs do not start inparallel, all else queuing
From: WAly at Mobinil.com (Wessam Aly)
Date: Wed, 13 Sep 2006 12:38:30 +0300
I had the problem in the max jobs per client in global attributes.
Thanks to all who have helped..
 
Jerry Vochteloo
Simon Weaver
Bobby Williams
Ian Fehring
Steve Haskins
 

Wessam Aly 
Senior UNIX & Storage Systems Admin. 
HPUX-CSA Certified Systems Administrator 



________________________________

From: WEAVER, Simon [mailto:simon.weaver at astrium.eads.net] 
Sent: Monday, 11 September, 2006 08:27
To: Wessam Aly; Haskins, Steve
Cc: veritas-bu at mailman.eng.auburn.edu
Subject: RE: [Veritas-bu] New Veritas installation - jobs do not start
inparallel, all else queuing


What about your Max Jobs setting on the master - make sure this is set
to a high number - 99 as an example.
 
Storage Unit must be set for a high number as well as the schedule for
the policy.
 
 

Regards

Simon Weaver
3rd Line Technical Support
Windows Domain Administrator 

EADS Astrium Limited, B23AA IM (DCS)
Anchorage Road, Portsmouth, PO3 5PU

Email: Simon.Weaver at Astrium-eads.net
<mailto:Simon.Weaver at Astrium-eads.net> 

        -----Original Message-----
        From: Wessam Aly [mailto:WAly at Mobinil.com] 
        Sent: 09 September 2006 17:11
        To: Haskins, Steve
        Cc: veritas-bu at mailman.eng.auburn.edu
        Subject: Re: [Veritas-bu] New Veritas installation - jobs do not
start inparallel, all else queuing
        
        
         
        no not a shadow copy, its in queueing state, even though the
other drive is sitting idle with no jobs.

        Wessam Aly 
        Senior UNIX & Storage Systems Admin. 
        HPUX-CSA Certified Systems Administrator 
        
________________________________

        From: Haskins, Steve [mailto:Steve.Haskins at bannerhealth.com] 
        Sent: Saturday, 09 September, 2006 16:08
        To: Wessam Aly
        Subject: RE: [Veritas-bu] New Veritas installation - jobs do not
start in parallel, all else queuing
        
        

        

        Is the one active job the system state or shadow copy
components? Since I updated to 5.1 from 4.5 this has been the behaviour.

         

        Regards

         

        
________________________________


        From: veritas-bu-bounces at mailman.eng.auburn.edu
[mailto:veritas-bu-bounces at mailman.eng.auburn.edu] On Behalf Of Wessam
Aly
        Sent: Saturday, September 09, 2006 5:18 AM
        To: veritas-bu at mailman.eng.auburn.edu
        Subject: [Veritas-bu] New veritas installation - jobs do not
start inparallel, all else queueing

         

        Hey all, 

        I just started a new instakllation of Veritas Netbackup
Entreprise 5.1 MP4. I have 2 LTO3 drives in an STK L500 library.

        The 2-drive storage unit is configured for MPX 3 and with no max
frag limit. 

        Whenever I start a new job (configured for multiple streams),
Always only one stream starts writing to one drive, the the rest of jobs
are idle. The other drive is sitting idle. The job is configured with 3
or more streams.

        What could be the problem ? 

        Thanks, 
        Wessam Aly 
        Senior UNIX & Storage Systems Admin. 

        
        
        *******
        IMPORTANT
        
        Confidentiality: This e-mail communication and any attachments
thereto contain information which is confidential and are intended only
for the use of the individuals or entities named above. If you are not
the intended recipient, you are hereby notified that any disclosure,
copying, distribution or the taking any action in reliance on the
contents of these documents is strictly prohibited and may be illegal.
Please notify us of your receipt of this e-mail in error and delete the
e-mail and any copies of it.
        
        Monitoring/Viruses: Mobinil may monitor all incoming & outgoing
e-mails in line with current legislation. Although we have taken steps
to ensure that this e-mail and attachments are free from any Virus, we
advise that in keeping with good computing practice the recipient should
ensure they are actually virus free.
        
        The Egyptian Company for Mobile Services (Mobinil) 
        www.mobinil.com
        *******


        *******
        IMPORTANT
        
        Confidentiality: This e-mail communication and any attachments
thereto contain information which is confidential and are intended only
for the use of the individuals or entities named above. If you are not
the intended recipient, you are hereby notified that any disclosure,
copying, distribution or the taking any action in reliance on the
contents of these documents is strictly prohibited and may be illegal.
Please notify us of your receipt of this e-mail in error and delete the
e-mail and any copies of it.
        
        Monitoring/Viruses: Mobinil may monitor all incoming & outgoing
e-mails in line with current legislation. Although we have taken steps
to ensure that this e-mail and attachments are free from any Virus, we
advise that in keeping with good computing practice the recipient should
ensure they are actually virus free.
        
        The Egyptian Company for Mobile Services (Mobinil) 
        www.mobinil.com
        *******
        

This email is for the intended addressee only.
If you have received it in error then you must not use, retain,
disseminate or otherwise deal with it.
Please notify the sender by return email.
The views of the author may not necessarily constitute the views of
Astrium Limited.
Nothing in this email shall bind Astrium Limited in any contract or
obligation.

Astrium Limited, Registered in England and Wales No. 2449259
Registered Office: Gunnels Wood Road, Stevenage, Hertfordshire, SG1 2AS,
England
        

*******
IMPORTANT

Confidentiality: This e-mail communication and any attachments thereto contain 
information which is confidential and are intended only for the use of the 
individuals or entities named above.  If you are not the intended recipient, 
you are hereby notified that any disclosure, copying, distribution or the 
taking any action in reliance on the contents of these documents is strictly 
prohibited and may be illegal.  Please notify us of your receipt of this e-mail 
in error and delete the e-mail and any copies of it.

Monitoring/Viruses: Mobinil may monitor all incoming & outgoing e-mails in line 
with current legislation. Although we have taken steps to ensure that this 
e-mail and attachments are free from any Virus, we advise that in keeping with 
good computing practice the recipient should ensure they are actually virus 
free.

The Egyptian Company for Mobile Services (Mobinil) 
www.mobinil.com
*******

-------------- next part --------------
An HTML attachment was scrubbed...
URL: 
http://mailman.eng.auburn.edu/pipermail/veritas-bu/attachments/20060913/200402d9/attachment.html

<Prev in Thread] Current Thread [Next in Thread>
  • [Veritas-bu] New Veritas installation - jobs do not start inparallel, all else queuing, Wessam Aly <=