Dave
That sounds good! I sadly DON'T have a DR plan of sort, but I have a process
where the Catalog tapes and ones to disk are replicated around a site - so
in the event of the Master going pear-shaped (and assuming the robot is all
ok!!), restore via bprecover same drive config / MP, ect and that has
worked.

But it would be nice to have another site solution similar to Paul, but
adapting this to make the process to moving over as painless as possible,
with minimal fuss.

Thanks

Regards

Simon Weaver
3rd Line Technical Support
Windows Domain Administrator

EADS Astrium Limited, B23AA IM (DCS)
Anchorage Road, Portsmouth, PO3 5PU

Email: Simon.Weaver at Astrium-eads.net



-----Original Message-----
From: Dave Markham [mailto:dave.markham at fjserv.net]
Sent: 01 August 2006 14:02
To: Paul Keating
Cc: veritas-bu at mailman.eng.auburn.edu
Subject: Re: [Veritas-bu] Disaster Recovery Site


I've done something similar which is adopted as a DR method by the customer.
Its perhaps not as fancy as below but carries the same important feature.
The master server at DR site is the same hostname as the Production site.
This was critical in getting the DR process to work.

All i do is backup to disk each day the catalouges of Prod site ( also to
tape ) and rsync them over to DR site backup server. The DR site backup
server has its own catalogue for backing the DR site up during normal
operation but in DR scenario i backup the DR catalogus (bpbackup -dpath etc
) and then recover the rsynced ones from production site (
bprecover) now my DR site knows about all the tapes used at production site
( where i also have an ITC and tapes sent offsite ) and so i can restore
from production machines onto DR machines.

Works a charm

Dave

Paul Keating wrote:
> Inline Tape Copy.
> 
> It's a Netbackup feature where two tapes are written simultaneously.
> 
> We've done several tests of "our" infrastructure, and it has worked
> well. We have a corporate test coming up soon.....hope that goes as
> well. The procedures and everything will be the same, so it should go
> fine, there will just be 20 times more people involved in testing
> their stuff, so it will be much more hectic.
> 
> Paul
> 
> --
>
>     -----Original Message-----
>     *From:* Sponsler, Michael [mailto:Michael.Sponsler at ngc.com]
>     *Sent:* July 31, 2006 1:26 PM
>     *To:* Paul Keating; veritas-bu at mailman.eng.auburn.edu
>     *Subject:* RE: [Veritas-bu] Disaster Recovery Site
>
>     Paul,
>     
>     What is ITC?  You say your tapes are replicated using ITC....
>     
>     That sounds like a decent plan.  Have you tested a DR event, and
>     has it worked out alright?
>     
>     --
>     Mike Sponsler
>     Michael.Sponlser at ngc.com <mailto:Michael.Sponlser at ngc.com>
>     Northrop Grumman
>
> ----------------------------------------------------------------------
> --
>
> ======================================================================
> ==============
>
> La version fran?aise suit le texte anglais.
>
> ----------------------------------------------------------------------
> --------------
>
> This email may contain privileged and/or confidential information, and
> the Bank of Canada does not waive any related rights. Any
> distribution, use, or copying of this email or the information it
> contains by other than the intended recipient is unauthorized. If you
> received this email in error please delete it immediately from your
> system and notify the sender promptly by email that you have done so.
>
> ----------------------------------------------------------------------
> --------------
>
> Le pr?sent courriel peut contenir de l'information privil?gi?e ou
> confidentielle. La Banque du Canada ne renonce pas aux droits qui s'y
> rapportent. Toute diffusion, utilisation ou copie de ce courriel ou
> des renseignements qu'il contient par une personne autre que le ou les
> destinataires d?sign?s est interdite Si vous recevez ce courriel par
> erreur, veuillez le supprimer imm?diatement et envoyer sans d?lai ?
> l'exp?diteur un message ?lectronique pour l'aviser que vous avez
> ?limin? de votre ordinateur toute copie du courriel re?u.
>  
> ----------------------------------------------------------------------
> --
>
> _______________________________________________
> Veritas-bu maillist  -  Veritas-bu at mailman.eng.auburn.edu
> http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
>  

_______________________________________________
Veritas-bu maillist  -  Veritas-bu at mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

This email is for the intended addressee only.
If you have received it in error then you must not use, retain, disseminate or 
otherwise deal with it.
Please notify the sender by return email.
The views of the author may not necessarily constitute the views of Astrium 
Limited.
Nothing in this email shall bind Astrium Limited in any contract or obligation.

Astrium Limited, Registered in England and Wales No. 2449259
Registered Office: Gunnels Wood Road, Stevenage, Hertfordshire, SG1 2AS, England


<Prev in Thread] Current Thread [Next in Thread>