Simon
One of our streams failed over the weekend and I just right clicked on
the failed stream in the activity monitor and selected Restart Job. Only
that stream re-ran. May be a 6.0 thing though.
Regards
Richard
________________________________
From: veritas-bu-bounces at mailman.eng.auburn.edu
[mailto:veritas-bu-bounces at mailman.eng.auburn.edu] On Behalf Of WEAVER,
Simon
Sent: Friday, 30 June 2006 1:38 am
To: 'Falk, Martin SZ/HZA-ITDS2';
veritas-bu at mailman.eng.auburn.edu
Subject: Re: [Veritas-bu] Question on Policies
Martin
BOOOOOOOOOOOO!! Thats not good is it :-((( but it what I have
been doing !
Regards
Simon Weaver
3rd Line Technical Support
Windows Domain Administrator
EADS Astrium Limited, B32AA IM (DCS)
Anchorage Road, Portsmouth, PO3 5PU
Email: Simon.Weaver at Astrium-eads.net
<mailto:Simon.Weaver at Astrium-eads.net>
-----Original Message-----
From: Falk, Martin SZ/HZA-ITDS2
[mailto:falkmrt at schaeffler.com]
Sent: 29 June 2006 13:53
To: WEAVER, Simon; veritas-bu at mailman.eng.auburn.edu
Subject: AW: [Veritas-bu] Question on Policies
No, as far as I know. You have to start the whole job
and cancel the stream that you don't need
________________________________
Von: WEAVER, Simon
[mailto:simon.weaver at astrium.eads.net]
Gesendet: Donnerstag, 29. Juni 2006 13:13
An: Falk, Martin SZ/HZA-ITDS2;
veritas-bu at mailman.eng.auburn.edu
Betreff: RE: [Veritas-bu] Question on Policies
Martin
Now that was my understanding! so really, I may as well
kick off a failed job within the SAME policy.
But can you kick off a STREAM rather than the whole lot?
(job has 8 streams)
Regards
Simon Weaver
3rd Line Technical Support
Windows Domain Administrator
EADS Astrium Limited, B32AA IM (DCS)
Anchorage Road, Portsmouth, PO3 5PU
Email: Simon.Weaver at Astrium-eads.net
<mailto:Simon.Weaver at Astrium-eads.net>
-----Original Message-----
From: Falk, Martin SZ/HZA-ITDS2
[mailto:falkmrt at schaeffler.com]
Sent: 29 June 2006 11:31
To: WEAVER, Simon;
veritas-bu at mailman.eng.auburn.edu
Subject: AW: [Veritas-bu] Question on Policies
Netbackup uses a combination of Policy name and
archive bit. If you restart broken jobs within another policy next time
policy 1 will not recognize that the jobs was already done.
Martin
________________________________
Von: veritas-bu-bounces at mailman.eng.auburn.edu
[mailto:veritas-bu-bounces at mailman.eng.auburn.edu] Im Auftrag von
WEAVER, Simon
Gesendet: Donnerstag, 29. Juni 2006 11:37
An: veritas-bu at mailman.eng.auburn.edu
Betreff: [Veritas-bu] Question on Policies
Guys
A quick question again about Policies
Scenario: One Policy does Weekly Full backups
and Cum Incr. - Policy Name is SERVER 1
I have created a 2nd Policy named
SERVER1_MANUAL, same settings as SERVER1, but this time not specified
any drives \ folders to backup.
If a stream fails on the FULL Backup in the
SERVER1 Policy, could I enable the 2nd policy to backup the stream that
failed?
Although this would work, I am starting to think
that when the SERVER1 Policy runs an incremental, it will treat the
streams that failed the full backup as a full backup and continue to do
so until a Full Backup has run at the end of the week.
Does that make sense? :-) Any guidance on this
would be great, as I want to narrow down how many policies I have.
Finally, if I get a failed stream, is there a
way to KICK OFF just a single stream if the window has closed? What I do
is kick off a MANUAL FULL, and kill the streams that I dont need a full
backup of.
Regards
Simon Weaver
3rd Line Technical Support
Windows Domain Administrator
EADS Astrium Limited, B32AA IM (DCS)
Anchorage Road, Portsmouth, PO3 5PU
Email: Simon.Weaver at Astrium-eads.net
<mailto:Simon.Weaver at Astrium-eads.net>
This email is for the intended addressee only.
If you have received it in error then you must not use, retain,
disseminate or otherwise deal with it.
Please notify the sender by return email.
The views of the author may not necessarily constitute the views of EADS
Astrium Limited.
Nothing in this email shall bind EADS Astrium Limited in any contract or
obligation.
EADS Astrium Limited, Registered in England and Wales No. 2449259
Registered Office: Gunnels Wood Road, Stevenage, Hertfordshire, SG1 2AS,
England
This email is for the intended addressee only.
If you have received it in error then you must not use, retain,
disseminate or otherwise deal with it.
Please notify the sender by return email.
The views of the author may not necessarily constitute the views of EADS
Astrium Limited.
Nothing in this email shall bind EADS Astrium Limited in any contract or
obligation.
EADS Astrium Limited, Registered in England and Wales No. 2449259
Registered Office: Gunnels Wood Road, Stevenage, Hertfordshire, SG1 2AS,
England
This email is for the intended addressee only.
If you have received it in error then you must not use, retain,
disseminate or otherwise deal with it.
Please notify the sender by return email.
The views of the author may not necessarily constitute the views of EADS
Astrium Limited.
Nothing in this email shall bind EADS Astrium Limited in any contract or
obligation.
EADS Astrium Limited, Registered in England and Wales No. 2449259
Registered Office: Gunnels Wood Road, Stevenage, Hertfordshire, SG1 2AS,
England
**********************************************************************
This electronic email and any files transmitted with it are intended
solely for the use of the individual or entity to whom they are addressed.
The views expressed in this message are those of the individual
sender and may not necessarily reflect the views of the Christchurch
City Council.
If you are not the correct recipient of this email please advise the
sender and delete.
Christchurch City Council
http://www.ccc.govt.nz
**********************************************************************
-------------- next part --------------
An HTML attachment was scrubbed...
URL:
http://mailman.eng.auburn.edu/pipermail/veritas-bu/attachments/20060630/5ee7ee21/attachment.html
|