Martin
What sort of files are on here? Any AV running? Is tracker.exe running on
the box? If so turn them both off?
What about Network configuration - is this all set to max throughput and not
auto / auto? Could be a Network related issue! You also mentioned VSS / VSP
is turned off correct?
Regards
Simon Weaver
3rd Line Technical Support
Windows Domain Administrator
EADS Astrium Limited, B32AA IM (DCS)
Anchorage Road, Portsmouth, PO3 5PU
Email: Simon.Weaver at Astrium-eads.net
-----Original Message-----
From: Falk, Martin SZ/HZA-ITDS2 [mailto:falkmrt at schaeffler.com]
Sent: 29 June 2006 10:23
To: WEAVER, Simon; veritas-bu at mailman.eng.auburn.edu
Subject: AW: [Veritas-bu] Status 14 on Cummulative Incremental
Total size is 680 GB with 38 GB free.
Rebootet several times. All drivers are up to date.
Regards
Martin
-----Urspr?ngliche Nachricht-----
Von: WEAVER, Simon [mailto:simon.weaver at astrium.eads.net]
Gesendet: Donnerstag, 29. Juni 2006 10:58
An: Falk, Martin SZ/HZA-ITDS2; veritas-bu at mailman.eng.auburn.edu
Betreff: RE: [Veritas-bu] Status 14 on Cummulative Incremental
Ummmm not looked into, but how much space is on D:?
Have you attempted to reboot the client lately and re-try?
Regards
Simon Weaver
3rd Line Technical Support
Windows Domain Administrator
EADS Astrium Limited, B32AA IM (DCS)
Anchorage Road, Portsmouth, PO3 5PU
Email: Simon.Weaver at Astrium-eads.net
-----Original Message-----
From: Falk, Martin SZ/HZA-ITDS2 [mailto:falkmrt at schaeffler.com]
Sent: 29 June 2006 09:25
To: veritas-bu at mailman.eng.auburn.edu
Subject: [Veritas-bu] Status 14 on Cummulative Incremental
Hello,
Does anybody experienced this failure?
Client Windows 2000
Full Backup on System State, C: and D: runs well
Cumulative Incremental on System State and C: runs well too Cummulative
Incremental on D: always fails with Status 14 (file write
failed)
Open File Backup is disabled
Master Solaris 5.0 MP4
Client Windows 2000 5.0 MP4
Thanks
Martin
_______________________________________________
Veritas-bu maillist - Veritas-bu at mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
This email is for the intended addressee only.
If you have received it in error then you must not use, retain, disseminate
or otherwise deal with it. Please notify the sender by return email. The
views of the author may not necessarily constitute the views of EADS Astrium
Limited. Nothing in this email shall bind EADS Astrium Limited in any
contract or obligation.
EADS Astrium Limited, Registered in England and Wales No. 2449259 Registered
Office: Gunnels Wood Road, Stevenage, Hertfordshire, SG1 2AS, England
This email is for the intended addressee only.
If you have received it in error then you must not use, retain, disseminate or
otherwise deal with it.
Please notify the sender by return email.
The views of the author may not necessarily constitute the views of EADS
Astrium Limited.
Nothing in this email shall bind EADS Astrium Limited in any contract or
obligation.
EADS Astrium Limited, Registered in England and Wales No. 2449259
Registered Office: Gunnels Wood Road, Stevenage, Hertfordshire, SG1 2AS, England
|