Veritas-bu

[Veritas-bu] NetBackup 6 and shell scripts question

2006-06-28 08:32:52
Subject: [Veritas-bu] NetBackup 6 and shell scripts question
From: ckstehman at pepco.com (ckstehman AT pepco DOT com)
Date: Wed, 28 Jun 2006 08:32:52 -0400
Look into "bpstart_notify" and "bpend_notify" scripts that you can install 
on your UNIX client. In "/usr/openv/netbackup/bin"
We use these to shutdown an Oracle Database before starting the backup and 
restarting the database
after the backup completes.  This should do what you want.

=============================
Carl Stehman
IT Distributed Services Team
Pepco Holdings, Inc.
202-331-6619
Pager 301-765-2703
ckstehman at pepco.com



"Dustin D'Amour" <dustind at coyotesolutions.com> 
Sent by: veritas-bu-bounces at mailman.eng.auburn.edu
06/27/2006 04:40 PM

To
<veritas-bu at mailman.eng.auburn.edu>
cc

Subject
[Veritas-bu] NetBackup 6 and shell scripts question






Is there a way to have NetBackup initiate a shell script to shutdown 
services then after that is completed the backup starts.  After the backup 
finishes have NetBackup initiate another script which restarts the 
services? 
 
Running NetBackup server on Suse Enterprise 9 and the client in the 
question is on Solaris 8.
 
Dustin D'Amour
Coyote Solutions Group
505.742.0066
www.coyotesolutions.com
 _______________________________________________
Veritas-bu maillist  -  Veritas-bu at mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


This Email message and any attachment may contain information that is
proprietary, legally privileged, confidential and/or subject to copyright
belonging to Pepco Holdings, Inc. or its affiliates ("PHI").  This Email is
intended solely for the use of the person(s) to which it is addressed.  If
you are not an intended recipient, or the employee or agent responsible for
delivery of this Email to the intended recipient(s), you are hereby notified
that any dissemination, distribution or copying of this Email is strictly
prohibited.  If you have received this message in error, please immediately
notify the sender and permanently delete this Email and any copies.  PHI
policies expressly prohibit employees from making defamatory or offensive
statements and infringing any copyright or any other legal right by Email
communication.  PHI will not accept any liability in respect of such
communications.
-------------- next part --------------
An HTML attachment was scrubbed...
URL: 
http://mailman.eng.auburn.edu/pipermail/veritas-bu/attachments/20060628/ef5d52f0/attachment.html