[Veritas-bu] Sg / sgen driver issue
2006-05-10 18:37:50
Your st.conf probably has something like:
name="st" class="scsi"
target=0 lun=0;
name="st" class="scsi"
target=1 lun=0;
You need to add lines like:
name="st" class="scsi"
target=0 lun=1;
name="st" class="scsi"
target=0 lun=2;
I personally added Luns 1-7 on targets 0-7. That possibly makes boot up
a little slower, but it also means the drives will be picked up almost
regardless of whatever silliness I might pull on the SAN. :-)
Regards,
T.
-----Original Message-----
From: Song, Young [mailto:Young.Song AT NOVELLUS DOT com]
Sent: Thursday, 11 May 2006 8:25 AM
To: Tristan Ball; veritas-bu AT mailman.eng.auburn DOT edu
Subject: RE: [Veritas-bu] Sg / sgen driver issue
Hi Tristan,
That sounds to be my case as well.
From the info for the one drive and router that are visible, how can I
identify and add the correct entry for the other tape drive into st.conf
file?
Thanks!
- Young
-----Original Message-----
From: Tristan Ball [mailto:Tristan.Ball AT vsl.com DOT au]
Sent: Wednesday, May 10, 2006 3:15 PM
To: Song, Young; veritas-bu AT mailman.eng.auburn DOT edu
Subject: RE: [Veritas-bu] Sg / sgen driver issue
Have a look at your st.conf. I have a MSL 6030, and it attaches to the
FC via a built in SCSI/FC router. That router presents the tape drives
as LUN's
1 & 2, with the controller as LUN 0.
By default, the solaris st only scans LUN 0, but that can be changed in
ST conf.
Regards,
Tristan.
-----Original Message-----
From: veritas-bu-admin AT mailman.eng.auburn DOT edu
[mailto:veritas-bu-admin AT mailman.eng.auburn DOT edu] On Behalf Of Song,
Young
Sent: Thursday, 11 May 2006 4:33 AM
To: 'veritas-bu AT mailman.eng.auburn DOT edu'
Subject: [Veritas-bu] Sg / sgen driver issue
I'm trying to set up Sun Fire-480R as a new backup server to replace an
old one and in a situation where I'm stuck and thus want to ask here.
I'm running Solaris 8 with all the latest Solaris patches including st
driver patch, etc. & latest SAN Foundation Kit 4.4.9.
And I have a FC-attached HP MSL 5060 library with 2 LTO-1 drives via
Brocade Silkworm switches.
After installing NetBackup v5.1, I tried following the steps in
MediaMgr_DeviceConfig_Guide.txt but no matter what I tried, I couldn't
have it see both tape drives properly and I believe it's something to do
with sg.conf, sg.links, & devlink.tab files. However, I may be wrong.
I tried all I could try with cfgadm, devfsadm, luxadm, zoning, etc. and
know that I have all the proper connections and the box can see the
library itself but not all the drives.
Anyone experienced similar things and have any advice?
Thank you in advance!!!
- Young
_______________________________________________
Veritas-bu maillist - Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
|
<Prev in Thread] |
Current Thread |
[Next in Thread>
|
- [Veritas-bu] Sg / sgen driver issue, Song, Young
- [Veritas-bu] Sg / sgen driver issue, Tristan Ball
- [Veritas-bu] Sg / sgen driver issue, Song, Young
- [Veritas-bu] Sg / sgen driver issue,
Tristan Ball <=
- [Veritas-bu] Sg / sgen driver issue, Song, Young
- [Veritas-bu] Sg / sgen driver issue, Song, Young
- [Veritas-bu] Sg / sgen driver issue, Song, Young
|
|
|