you can't change the hostname after the netbackup install (err, well you
can if you're into masochism).
=20
set the machine up with the same hostname as your existing NBU master,
but do it on a lab network or similar.
or don't put the system in NIS, so it doesn't register.....
then set up the netwokr interface with a different hostname Ip.
=20
f'rinstance, I have two netbackup masters (primary and failover) and
each have the same hostname.....neither have a network interface with
that name, but it's the name Netbackup recognizes.
=20
something like this.
=20
both machines named "NBUMaster" (hostname returns NBUMaster)
=20
Primary master has 2 NICs
10.1.1.1 NBUMaster-pri1
10.1.1.2 NBUMaster-pri2
=20
Standby master has 2 NICs
10.2.1.1 NBUMaster-sec1
10.2.1.2 NBUMaster-sec2
=20
=20
-----Original Message-----
From: veritas-bu-admin AT mailman.eng.auburn DOT edu
[mailto:veritas-bu-admin AT mailman.eng.auburn DOT edu] On Behalf Of Joseph
Despres
Sent: February 6, 2006 9:42 AM
To: veritas-bu AT mailman.eng.auburn DOT edu
Subject: [Veritas-bu] Need some clarification on moving a Master
to a more powerful system..
=09
=09
Hey All......=20
=09
I need some clarification on moving Netbackup 4.5 fp9 from a
220r to a 440r.....=20
=09
Note: Hostname and IP will stay the same....=20
=09
Can I configure Netbackup on the new system with a temp
hostname/IP. Then when the time comes=20
rename the new system with the current hostname/IP. And perform
a bprecover to recover the catalog info.....=20
=09
Do I need to install Netbackup after the new box has been
changed hostname/ip wise to the current info?=20
=09
Thanks....=20
=09
=09
Joe Despres...........
=09
------------------------------------------------------------------------
----------------
This is a PRIVATE message. If you are not the intended
recipient, please delete without copying and kindly advise us by e-mail
of the mistake in delivery. NOTE: Regardless of content, this e-mail
shall not operate to bind CSC to any order or other contract unless
pursuant to explicit written agreement or government initiative
expressly permitting the use of e-mail for such purpose.
=09
------------------------------------------------------------------------
----------------
------_=_NextPart_001_01C62B2D.55B0392D
Content-Type: text/html;
charset="us-ascii"
Content-Transfer-Encoding: quoted-printable
<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN">
<HTML><HEAD><TITLE>Message</TITLE>
<META http-equiv=3DContent-Type content=3D"text/html; =
charset=3Dus-ascii">
<META content=3D"MSHTML 6.00.2800.1170" name=3DGENERATOR></HEAD>
<BODY>
<DIV><SPAN class=3D706534814-06022006><FONT face=3DArial color=3D#800000 =
size=3D2>you=20
can't change the hostname after the netbackup install (err, well you can =
if=20
you're into masochism).</FONT></SPAN></DIV>
<DIV><SPAN class=3D706534814-06022006><FONT face=3DArial color=3D#800000 =
size=3D2></FONT></SPAN> </DIV>
<DIV><SPAN class=3D706534814-06022006><FONT face=3DArial color=3D#800000 =
size=3D2>set=20
the machine up with the same hostname as your existing NBU master, but =
do it on=20
a lab network or similar.</FONT></SPAN></DIV>
<DIV><SPAN class=3D706534814-06022006><FONT face=3DArial color=3D#800000 =
size=3D2>or=20
don't put the system in NIS, so it doesn't =
register.....</FONT></SPAN></DIV>
<DIV><SPAN class=3D706534814-06022006><FONT face=3DArial color=3D#800000 =
size=3D2>then=20
set up the netwokr interface with a different hostname =
Ip.</FONT></SPAN></DIV>
<DIV><SPAN class=3D706534814-06022006><FONT face=3DArial color=3D#800000 =
size=3D2></FONT></SPAN> </DIV>
<DIV><SPAN class=3D706534814-06022006><FONT face=3DArial color=3D#800000 =
size=3D2>f'rinstance, I have two netbackup masters (primary and =
failover) and each=20
have the same hostname.....neither have a network interface with that =
name, but=20
it's the name Netbackup recognizes.</FONT></SPAN></DIV>
<DIV><SPAN class=3D706534814-06022006><FONT face=3DArial color=3D#800000 =
size=3D2></FONT></SPAN> </DIV>
<DIV><SPAN class=3D706534814-06022006><FONT face=3DArial color=3D#800000 =
size=3D2>something like this.</FONT></SPAN></DIV>
<DIV><SPAN class=3D706534814-06022006><FONT face=3DArial color=3D#800000 =
size=3D2></FONT></SPAN> </DIV>
<DIV><SPAN class=3D706534814-06022006><FONT face=3DArial color=3D#800000 =
size=3D2>both=20
machines named "NBUMaster" (hostname returns =
NBUMaster)</FONT></SPAN></DIV>
<DIV><SPAN class=3D706534814-06022006><FONT face=3DArial color=3D#800000 =
size=3D2></FONT></SPAN> </DIV>
<DIV><SPAN class=3D706534814-06022006><FONT face=3DArial color=3D#800000 =
size=3D2>Primary master has 2 NICs</FONT></SPAN></DIV>
<DIV><SPAN class=3D706534814-06022006><FONT face=3DArial color=3D#800000 =
size=3D2>10.1.1.1 =
NBUMaster-pri1</FONT></SPAN></DIV>
<DIV><SPAN class=3D706534814-06022006><FONT face=3DArial color=3D#800000 =
size=3D2>10.1.1.2 NBUMaster-pri2</FONT></SPAN></DIV>
<DIV><SPAN class=3D706534814-06022006><FONT face=3DArial color=3D#800000 =
size=3D2></FONT></SPAN> </DIV>
<DIV><SPAN class=3D706534814-06022006><FONT face=3DArial color=3D#800000 =
size=3D2>Standby master has 2 NICs</FONT></SPAN></DIV>
<DIV><SPAN class=3D706534814-06022006><FONT face=3DArial color=3D#800000 =
size=3D2>10.2.1.1 NBUMaster-sec1</FONT></SPAN></DIV>
<DIV><SPAN class=3D706534814-06022006><FONT face=3DArial color=3D#800000 =
size=3D2>10.2.1.2 NBUMaster-sec2</FONT></SPAN></DIV>
<DIV><SPAN class=3D706534814-06022006><FONT face=3DArial color=3D#800000 =
size=3D2></FONT></SPAN> </DIV>
<DIV><SPAN class=3D706534814-06022006><FONT face=3DArial color=3D#800000 =
size=3D2></FONT></SPAN> </DIV>
<BLOCKQUOTE=20
style=3D"PADDING-LEFT: 5px; MARGIN-LEFT: 5px; BORDER-LEFT: #800000 2px =
solid; MARGIN-RIGHT: 0px">
<DIV></DIV>
<DIV class=3DOutlookMessageHeader lang=3Den-us dir=3Dltr =
align=3Dleft><FONT=20
face=3DTahoma size=3D2>-----Original Message-----<BR><B>From:</B>=20
veritas-bu-admin AT mailman.eng.auburn DOT edu=20
[mailto:veritas-bu-admin AT mailman.eng.auburn DOT edu] <B>On Behalf Of =
</B>Joseph=20
Despres<BR><B>Sent:</B> February 6, 2006 9:42 AM<BR><B>To:</B>=20
veritas-bu AT mailman.eng.auburn DOT edu<BR><B>Subject:</B> [Veritas-bu] Need
=
some=20
clarification on moving a Master to a more powerful=20
system..<BR><BR></FONT></DIV><BR><FONT face=3Dsans-serif size=3D2>Hey=20
All......</FONT> <BR><BR><FONT face=3Dsans-serif size=3D2>I need some=20
clarification on moving Netbackup 4.5 fp9 from a 220r to a =
440r.....</FONT>=20
<BR><BR><FONT face=3Dsans-serif size=3D2>Note: Hostname and IP =
will stay the=20
same....</FONT> <BR><BR><FONT face=3Dsans-serif size=3D2>Can I =
configure Netbackup=20
on the new system with a temp hostname/IP. Then when the time=20
comes</FONT> <BR><FONT face=3Dsans-serif size=3D2>rename the new =
system with the=20
current hostname/IP. And perform a bprecover to recover the =
catalog=20
info.....</FONT> <BR><BR><FONT face=3Dsans-serif size=3D2>Do I need to =
install=20
Netbackup after the new box has been changed hostname/ip wise to the =
current=20
info?</FONT> <BR><BR><FONT face=3Dsans-serif size=3D2>Thanks.... =
</FONT><BR><FONT=20
face=3Dsans-serif size=3D2><BR></FONT><BR><FONT face=3Dsans-serif =
size=3D2>Joe=20
=
Despres...........<BR>---------------------------------------------------=
-------------------------------------<BR>This=20
is a PRIVATE message. If you are not the intended recipient, please =
delete=20
without copying and kindly advise us by e-mail of the mistake in =
delivery.=20
NOTE: Regardless of content, this e-mail shall not operate to bind CSC =
to any=20
order or other contract unless pursuant to explicit written agreement =
or=20
government initiative expressly permitting the use of e-mail for such=20
=
purpose.<BR>-------------------------------------------------------------=
---------------------------</FONT></BLOCKQUOTE></BODY></HTML>
=00
------_=_NextPart_001_01C62B2D.55B0392D--
--JmJO.4325qfzHf.1tWnu2.BSG1hzL
Content-Type: text/plain; charset=utf-8
Content-Transfer-Encoding: quoted-printable
Content-Disposition: inline
=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=
=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=
=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=
=3D=3D=3D=3D=3D=3D=3D=3D=3D
La version fran=C3=A7aise suit le texte anglais.
---------------------------------------------------------------------------=
---------
This email message from the Bank of Canada is given in good faith, and shal=
l not be
binding or construed as constituting any obligation on the part of the Bank.
This email may contain privileged and/or confidential information, and the =
Bank of
Canada does not waive any related rights. Any distribution, use, or copying=
of this
email or the information it contains by other than the intended recipient is
unauthorized. If you received this email in error please delete it immediat=
ely from
your system and notify the sender promptly by email that you have done so.=20
Recipients are advised to apply their own virus checks to this message upon=
receipt.
---------------------------------------------------------------------------=
---------
L'information communiqu=C3=A9e dans les courriels en provenance de la Banqu=
e du Canada
est soumise de bonne foi, mais elle ne saurait lier la Banque et ne doit au=
cunement
=C3=AAtre interpr=C3=A9t=C3=A9e comme constituant une obligation de sa part.
Le pr=C3=A9sent courriel peut contenir de l'information privil=C3=A9gi=C3=
=A9e ou confidentielle.
La Banque du Canada ne renonce pas aux droits qui s'y rapportent. Toute dif=
fusion,
utilisation ou copie de ce courriel ou des renseignements qu'il contient pa=
r une
personne autre que le ou les destinataires d=C3=A9sign=C3=A9s est interdite=
Si vous recevez
ce courriel par erreur, veuillez le supprimer imm=C3=A9diatement et envoyer=
sans d=C3=A9lai =C3=A0
l'exp=C3=A9diteur un message =C3=A9lectronique pour l'aviser que vous avez =
=C3=A9limin=C3=A9 de votre
ordinateur toute copie du courriel re=C3=A7u.
D=C3=A8s la r=C3=A9ception du pr=C3=A9sent message, le ou les destinataires=
doivent activer leur
programme de d=C3=A9tection de virus pour =C3=A9viter toute contamination p=
ossible.
--JmJO.4325qfzHf.1tWnu2.BSG1hzL--
|