Subject: [Veritas-bu] Moving tapes from offsite to onsite how to?
From: austin.murphy AT gmail DOT com (Austin Murphy)
Date: Thu, 19 Jan 2006 18:12:09 -0500
You need to have the tape put back into the robot (assuming you are
using one) and inventoried.  There is a command "vltinject" for doing
just that.   Make sure to delete the containers once they are empty. 
"vltcontainers"   Read the man pages for both.

Austin Murphy


On 1/19/06, Ed Wilts <ewilts AT ewilts DOT org> wrote:
> On Thu, Jan 19, 2006 at 04:36:53PM -0500, Hindle, Greg wrote:
> > Nb 5.1 mp4 Solaris 9
> >
> >
> > When you manually move a tape form offsite storage to onsite, what
> > process/commands do you run to accomplish this so that vault knows the
> > tape has been moved onsite?
>
> We simply go the GUI and re-inventory the library, checking the vault to
> empty the cap first.  NetBackup takes care of the rest.  We have a
> Solaris master, 5.0MP6, with an L700, but just fire up the GUI on our
> Windows media server since it's easier.
>
>         .../Ed
>
> --
> Ed Wilts, Mounds View, MN, USA
> mailto:ewilts AT ewilts DOT org