Date: Thu, 19 Jan 2006 21:38:05 +0000
I spoke to a colleague who deals with Windows, and he tells me that there 
is an option that can be set with the SP to not over-write OEM drivers, 
which we use.  Otherwise we found some of our HP servers with onboard RAID 
cannot be booted.

So I suggest, check that out and make whoever is doing your SP1 patching 
do so too.

William D L Brown




ida3248b AT post.cybercity DOT dk 
Sent by: veritas-bu-admin AT mailman.eng.auburn DOT edu
19-Jan-2006 12:56
 
To
william.d.brown AT gsk DOT com, veritas-bu AT mailman.eng.auburn DOT edu
cc
veritas-bu-admin AT mailman.eng.auburn DOT edu
Subject
Re: [Veritas-bu] Blocksize problem after upgrading EMC powerpath ( UPDATE)






I have tried, but it seems that the emulex driver detects that SP1 is 
installed and then create the emulexhbaapi.dll in system32. I'm also 
afraid 
that the next windows update will overwrite hbaapi.dll if isn't the 
microsoft 
one.

Regards
Michael

On Thu, 19 Jan 2006 09:59:14 +0000, william.d.brown wrote
> Well at a guess I would re-apply the Emulex driver to the HBAs.  Go 
> into device manager, right click on the HBA, and ask to Update 
> Driver.   If you tell it to look in /windows/system32 for the driver 
> it may find it, without you needing the CD.   Excuse me being a bit 
> vague, I have not tried it.  You can also check if you look at the 
> Driver Details tab just which files & driver it is using, I guess 
> you will see it using hbaapi.dll.  At least you will be able to see 
> if you succeed in changing it.
> 
> William D L Brown
> 
> ida3248b AT post.cybercity DOT dk 
> Sent by: veritas-bu-admin AT mailman.eng.auburn DOT edu
> 18-Jan-2006 15:56
> 
> To
> veritas-bu AT mailman.eng.auburn DOT edu
> cc
> 
> Subject
> [Veritas-bu] Blocksize problem after upgrading EMC powerpath ( UPDATE)
> 
> Hello All
> 
> I have now by trial and error figured out that it wasn't EMC 
> powerpath, but Windows 2003 SP1 which puts a microsoft hbaapi.dll 
> into system32 in place of the emulex one.
> 
> At the moment there's hbaapi.dll (from microsoft, 64Kb limit) and 
> emulexhbaapi.dll (at least 256kb) in system32 on the servers in 
question.
> 
> Now I just need to figure how to get the tape drivers to use the 
> emulexhbaapi.dll, any ideas ?
> 
> Regards
> Michael
> 
> --
> Cybercity Webhosting (http://www.cybercity.dk)
> 
> _______________________________________________
> Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
> http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
> 
> _______________________________________________
> Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
> http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


--
Cybercity Webhosting (http://www.cybercity.dk)

_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu





<Prev in Thread] Current Thread [Next in Thread>