Veritas-bu

[Veritas-bu] New SUN Server build

2004-04-08 13:18:58
Subject: [Veritas-bu] New SUN Server build
From: Melanie.Zink AT bankofamerica DOT com (Zink, Melanie)
Date: Thu, 08 Apr 2004 10:18:58 -0700
You can also change it in the Windows registry.  
HKLM\Software\VERITAS\NetBackup\CurrentVersion\Config Server: entry.

-----Original Message-----
From: veritas-bu-admin AT mailman.eng.auburn DOT edu
[mailto:veritas-bu-admin AT mailman.eng.auburn DOT edu]On Behalf Of mark
Sent: Thursday, April 08, 2004 10:11 AM
To: Nash, Ebon; 'William J Maniates'
Cc: 'Coco, Samuel (Cont, ARL/CISD)'; veritas-bu AT mailman.eng.auburn DOT edu;
veritas-bu-admin AT mailman.eng.auburn DOT edu
Subject: RE: [Veritas-bu] New SUN Server build


On windows clients, you can just select all the clients click properties
this will edit all clients at once, and update the master server for all of
them - just remember you need to add the new master to the server list
before you remove the old master, otherwise it will be a re-install as you
will not have an authorised server to update the properties. Other than
that, doesnt require a re-install ( or even a reboot ).

Regards
Mark



-----Original Message-----
From: veritas-bu-admin AT mailman.eng.auburn DOT edu
[mailto:veritas-bu-admin AT mailman.eng.auburn DOT edu]On Behalf Of Nash, Ebon
Sent: 08 April 2004 16:29
To: 'William J Maniates'; Nash, Ebon
Cc: 'Coco, Samuel (Cont, ARL/CISD)';
'veritas-bu AT mailman.eng.auburn DOT edu';
veritas-bu-admin AT mailman.eng.auburn DOT edu
Subject: RE: [Veritas-bu] New SUN Server build


Now that you mention it I think the reinstall is only required on Windows
servers.  In fact, I believe in the windows client GUI that you can't edit
the master server name.  It is something that should definitely be tested
before changing master server names.


Ebon Nash

-----Original Message-----
From: William J Maniates [mailto:wmaniates AT csc DOT com]
Sent: Thursday, April 08, 2004 10:58 AM
To: Nash, Ebon
Cc: 'Coco, Samuel (Cont, ARL/CISD)';
'veritas-bu AT mailman.eng.auburn DOT edu';
veritas-bu-admin AT mailman.eng.auburn DOT edu
Subject: RE: [Veritas-bu] New SUN Server build



I believe you can just add a "SERVER = <new master>" entry to your clients
bp.conf files.  We just had a do all script append the server entry line
onto the bp.conf file of all clients.  You do not even have to remove the
old master server entry.  This worked for unix anyway, not sure about
Windows.

Bill Maniates



----------------------------------------------------------------------------
------------

This is a PRIVATE message. If you are not the intended recipient, please
delete without copying and kindly advise us by e-mail of the mistake in
delivery. NOTE: Regardless of content, this e-mail shall not operate to
bind CSC to any order or other contract unless pursuant to explicit written
agreement or government initiative expressly permitting the use of e-mail
for such purpose.
----------------------------------------------------------------------------
------------






                      "Nash, Ebon"

                      <Ebon_Nash               To:      "'Coco, Samuel
(Cont, ARL/CISD)'" <scoco AT arl.army DOT mil>,
                      @compuware.com>
"'veritas-bu AT mailman.eng.auburn DOT edu'" <veritas-bu AT mailman.eng.auburn 
DOT edu>

                      Sent by:                 cc:

                      veritas-bu-admin         Subject: RE: [Veritas-bu] New
SUN Server build




                      04/08/2004 07:40

                      AM









  FYI/Reminder,

  If you plan on making this a new master with a different name, restoring
  from old data may require some extra work.  This is because I'm almost
  positive that a client can have only one master, and to change the master
  requires a reinstall of the NB client app for each client.  So you will
  initially have to reinstall the client on all your machines.
  Additionally, you will have to do this again to the specific client you
  wish to restore from a old backup on the old master server.  If I am
  wrong I'm sure someone will correct me


  Ebon Nash
        -----Original Message-----
        From: veritas-bu-admin AT mailman.eng.auburn DOT edu
        [mailto:veritas-bu-admin AT mailman.eng.auburn DOT edu]On Behalf Of 
Coco,
        Samuel (Cont, ARL/CISD)
        Sent: Thursday, April 08, 2004 6:38 AM
        To: veritas-bu AT mailman.eng.auburn DOT edu
        Subject: [Veritas-bu] New SUN Server build

        Folks,

             We are preparing to build a new Master/media server.  It will
        be a SUN V440 w/ 4-1.06 GHz, 8 GB RAM, 4-36 GB Ultra320 SCSI
        (internally mirrored for 2), 2 GigE MMF fiber cards, 2- Dual FC
        interface and 1 PCI dual channel Ultra 3 diff SCSI host adapter.
        Attached externally will be a SUN StorEdge D2 Ultra160 SCSI 4-36 GB
        drives to start (mirrored).  Our intent is to have the internal
        drives only for OS and swap and to use the D2 for the netbackup and
        DB.  The silo (either an ADIC Scalar 2000 or a Quantum PX720), will
        be connected via a set of the FCs.  The OS will be Sol 9.0
        (secured) and initially the VERITAS app will be 4.5 FP5/6 with a
        planned upgrade to 5.1 when available if proven reliable.

             We are looking for any suggestions, recommendations, warnings,
        etc that may be available based upon your experiences.  Including,
        any 'tweaks' to the OS as we have done on our current solution (an
        E3000 / STK 9710) and have shared in previous mailings.

             Our current thoughts are to build the system - test - debug -
        test - approve and then to begin redirection of clients on a
        scheduled basis from the old to the new.  We do not intend to
        migrate the catalogue over.  Instead we will retain both units
        active until the bulk of the media is expired and then 'import' any
        minimal tapes that remain.

             Again - your thoughts would be greatly appreciated.



        Thank you,


        Samuel J. Coco, STG
        Functional Area Manager, ARL
        Sr UNIX Administrator
        BELL      301 394-1151 DSN 290
        CELL (B) 240 398-7121 / (H)443 496-1623
        HOME     410 604-2415
        Email  scoco AT arl.army DOT mil








The contents of this e-mail are intended for the named addressee only. It
contains information that may be confidential. Unless you are the named
addressee or an authorized designee, you may not copy or use it, or
disclose it to anyone else. If you received it in error please notify us
immediately and then destroy it.












The contents of this e-mail are intended for the named addressee only. It
contains information that may be confidential. Unless you are the named
addressee or an authorized designee, you may not copy or use it, or disclose
it to anyone else. If you received it in error please notify us immediately
and then destroy it.

_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu



_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

<Prev in Thread] Current Thread [Next in Thread>