Hello Keath
=20
You can switch from MP to FP at the same or greater level. So if you are =
at MP5 you can go to FP5 or FP6.=20
len
-----Original Message-----
From: Marx, Keath [mailto:Keath.Marx AT anthem DOT com]
Sent: Wednesday, January 14, 2004 11:57 AM
To: veritas-bu AT mailman.eng.auburn DOT edu
Subject: RE: [Veritas-bu] FC L180 woes
The biggest problem I can see straight of the bat is an MP on a FP =
install. It has been my understanding that you must chose and stick =
with either the FP releases or the MP releases. They are not supposed =
to be interchangeable.
-----Original Message-----
From: veritas-bu-admin AT mailman.eng.auburn DOT edu@AICI On Behalf Of "Smith, =
Kevin" <kevin.m.smith AT siemens DOT com>
Sent: Wednesday, January 14, 2004 8:52 AM
To: veritas-bu AT mailman.eng.auburn DOT edu
Subject: [Veritas-bu] FC L180 woes
All,=20
Config : V480, X6768A FC HBA, L180 with 6 x LTO-II Fibre drives =
connected via SANBridge x16 2GB switch. Drives are in 2 split zones [3 =
in each]. Host has NB DC 4.5FP3 patched to MP5 installed.=20
Problem: Drives are only running about 20M per sec, in line tape copy =
is VERY slow [slower than our SCSI L60], restores are even worse. In =
fact I think I can safely say at the moment our 100k L180 is only =
slightly faster than our old SCSI L60.
Can anyone shed any light on why? If so - what can we do about it?=20
Thanks people.=20
----------------------------------------------------
Kev Smith
Unix Systems Administrator.=20
Operational Support, IND Croydon.=20
* E-Mail : kevin.m.smith AT siemens DOT com=20
( Tel : 020 8760 4849=20
( Mobile : 07808 828595=20
----------------------------------------------------=20
Siemens Business Services Ltd
This e-mail contains confidential information and is for the exclusive =
use of the addressee/s. If you are not the addressee, then any =
distribution, copying or use of this e-mail is prohibited. If received =
in error, please advise the sender and delete it immediately. We accept =
no liability for any loss or damage suffered by any person arising from =
use of this e-mail.
Siemens Business Services=20
Registered No: 1203466 England
Registered Office: Siemens House, Olbury, Bracknell, =
Berkshire,=20
RG12 8FZ=20
CONFIDENTIALITY NOTICE: This e-mail message, including any attachments, =
is for the sole use of the intended recipient(s) and may contain =
confidential and privileged information or otherwise be protected by =
law. Any unauthorized review, use, disclosure or distribution is =
prohibited. If you are not the intended recipient, please contact the =
sender by reply e-mail and destroy all copies of the original message.=20
------_=_NextPart_001_01C3DAE6.82D077D4
Content-Type: text/html;
charset="iso-8859-1"
Content-Transfer-Encoding: quoted-printable
<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN">
<HTML><HEAD>
<META HTTP-EQUIV=3D"Content-Type" CONTENT=3D"text/html; =
charset=3Diso-8859-1">
<TITLE>RE: [Veritas-bu] FC L180 woes</TITLE>
<META content=3D"MSHTML 6.00.2800.1276" name=3DGENERATOR></HEAD>
<BODY>
<DIV><SPAN class=3D211463521-14012004><FONT face=3DArial color=3D#0000ff =
size=3D2>Hello=20
Keath</FONT></SPAN></DIV>
<DIV><SPAN class=3D211463521-14012004><FONT face=3DArial color=3D#0000ff =
size=3D2></FONT></SPAN> </DIV>
<DIV><SPAN class=3D211463521-14012004><FONT face=3DArial color=3D#0000ff =
size=3D2>You=20
can switch from MP to FP at the same or greater level. So if you are at =
MP5 you=20
can go to FP5 or FP6. </FONT></SPAN></DIV>
<DIV><SPAN class=3D211463521-14012004><FONT face=3DArial color=3D#0000ff =
size=3D2>len</FONT></SPAN></DIV>
<BLOCKQUOTE>
<DIV class=3DOutlookMessageHeader dir=3Dltr align=3Dleft><FONT =
face=3DTahoma=20
size=3D2>-----Original Message-----<BR><B>From:</B> Marx, Keath=20
[mailto:Keath.Marx AT anthem DOT com]<BR><B>Sent:</B> Wednesday, January 14, =
2004=20
11:57 AM<BR><B>To:</B> =
veritas-bu AT mailman.eng.auburn DOT edu<BR><B>Subject:</B>=20
RE: [Veritas-bu] FC L180 woes<BR><BR></FONT></DIV>
<P align=3Dleft><FONT face=3DArial color=3D#000080 size=3D2>The</FONT> =
<FONT=20
face=3DArial color=3D#000080 size=3D2>biggest</FONT><FONT face=3DArial =
color=3D#000080=20
size=3D2> problem I can see straight of the bat is an MP on a FP =
install. =20
It has been my understanding that you must chose and stick with either =
the FP=20
releases or the MP releases. </FONT> <FONT face=3DArial =
color=3D#000080=20
size=3D2>T</FONT><FONT face=3DArial color=3D#000080 =
size=3D2>hey</FONT><FONT=20
face=3DArial color=3D#000080 size=3D2></FONT> <FONT face=3DArial =
color=3D#000080=20
size=3D2>are not supposed to be</FONT> <FONT face=3DArial =
color=3D#000080=20
size=3D2>interchangeable</FONT><FONT face=3DArial color=3D#000080=20
size=3D2>.</FONT></P>
<UL>
<UL>
<P align=3Dleft><FONT face=3DTahoma size=3D2>-----Original=20
Message-----<BR></FONT><B></B><B><FONT face=3DTahoma=20
size=3D2>From:</FONT></B><FONT face=3DTahoma size=3D2>=20
veritas-bu-admin AT mailman.eng.auburn DOT edu@AICI</FONT><B></B><B> =
<FONT=20
face=3DTahoma size=3D2>On Behalf Of</FONT></B> <FONT face=3DTahoma =
size=3D2>"Smith, Kevin"=20
<kevin.m.smith AT siemens DOT com><BR></FONT><B></B><B><FONT =
face=3DTahoma=20
size=3D2>Sent:</FONT></B><FONT face=3DTahoma size=3D2> Wednesday, =
January 14,=20
2004 8:52 AM<BR></FONT><B></B><B><FONT face=3DTahoma=20
size=3D2>To:</FONT></B><FONT face=3DTahoma size=3D2>=20
veritas-bu AT mailman.eng.auburn DOT edu<BR></FONT><B></B><B><FONT =
face=3DTahoma=20
size=3D2>Subject:</FONT></B><FONT face=3DTahoma size=3D2> =
[Veritas-bu] FC L180=20
woes</FONT></P><BR>
<P align=3Dleft><FONT face=3D"Tms Rmn" color=3D#000000 =
size=3D2>All,</FONT><FONT=20
face=3D"Tms Rmn" color=3D#000000> </FONT></P>
<P align=3Dleft><FONT face=3D"Tms Rmn" color=3D#000000 =
size=3D2>Config : V480,=20
X6768A FC HBA, L180 with 6 x LTO-II Fibre drives connected via =
SANBridge=20
x16 2GB switch. Drives are in 2 split zones [3 in each]. Host has =
NB DC=20
4.5FP3 patched to MP5 installed. </FONT></P>
<P align=3Dleft><FONT face=3D"Tms Rmn" color=3D#000000 =
size=3D2>Problem: Drives=20
are only running about 20M per sec, in line tape copy is VERY slow =
[slower=20
than our SCSI L60], restores are even worse. In fact I think I can =
safely=20
say at the moment our 100k L180 is only slightly faster than our =
old SCSI=20
L60.</FONT></P>
<P align=3Dleft><FONT face=3D"Tms Rmn" color=3D#000000 =
size=3D2>Can anyone shed=20
any light on why? If so - what can we do about it?</FONT><FONT=20
face=3D"Tms Rmn" color=3D#000000> </FONT></P>
<P align=3Dleft><FONT face=3D"Tms Rmn" color=3D#000000 =
size=3D2>Thanks=20
people.</FONT><FONT face=3D"Tms Rmn" color=3D#000000> </FONT></P>
<UL>
<UL>
<P align=3Dleft><FONT face=3D"Tms Rmn" color=3D#000000=20
=
size=3D2>----------------------------------------------------</FONT></P>
<P align=3Dleft><B><FONT face=3D"Tms Rmn" color=3D#000000 =
size=3D2>Kev=20
Smith</FONT></B></P>
<P align=3Dleft><B><FONT face=3D"Tms Rmn" color=3D#000000 =
size=3D2>Unix=20
Systems Administrator. </FONT></B></P>
<P align=3Dleft><B><FONT face=3D"Tms Rmn" color=3D#000000 =
size=3D2>Operational=20
Support, IND Croydon.</FONT></B><FONT face=3D"Tms Rmn" =
color=3D#000000>=20
</FONT></P>
<P align=3Dleft><FONT face=3D"Tms Rmn" color=3D#000000 =
size=3D2>*=20
E-Mail :=20
kevin.m.smith AT siemens DOT com</FONT><FONT face=3D"Tms Rmn" =
color=3D#000000>=20
</FONT></P>
<P align=3Dleft><FONT face=3D"Tms Rmn" color=3D#000000 =
size=3D2>(=20
Tel : =
020 8760=20
4849</FONT><FONT face=3D"Tms Rmn" color=3D#000000> </FONT></P>
<P align=3Dleft><FONT face=3D"Tms Rmn" color=3D#000000 =
size=3D2>(</FONT><FONT=20
face=3D"Tms Rmn" color=3D#000000></FONT> <FONT face=3D"Tms =
Rmn"=20
color=3D#000000 =
size=3D2>Mobile =20
: 07808 828595</FONT><FONT face=3D"Tms Rmn" color=3D#000000> =
</FONT></P>
<P align=3Dleft><FONT face=3D"Tms Rmn" color=3D#000000=20
=
size=3D2>----------------------------------------------------</FONT><FONT=
=20
face=3D"Tms Rmn" color=3D#000000> </FONT></P>
<P align=3Dleft><B><U><FONT face=3D"Tms Rmn" =
color=3D#000000>Siemens=20
Business Services Ltd</FONT></U></B></P>
<P align=3Dleft><B><FONT face=3D"Tms Rmn" color=3D#000000 =
size=3D2>This e-mail=20
contains confidential information and is for the exclusive use =
of the=20
addressee/s. If you are not the addressee, then any =
distribution,=20
copying or use of this e-mail is prohibited. If received in =
error,=20
please advise the sender and delete it immediately. We accept =
no=20
liability for any loss or damage suffered by any person =
arising from=20
use of this e-mail.</FONT></B></P>
<P align=3Dleft><B><FONT face=3D"Tms Rmn" color=3D#000000 =
size=3D2>Siemens=20
Business Services</FONT></B><FONT face=3D"Tms Rmn" =
color=3D#000000>=20
</FONT></P>
<P align=3Dleft><B><FONT face=3D"Tms Rmn" color=3D#000000 =
size=3D2>Registered=20
No: 1203466 England</FONT></B></P>
<P align=3Dleft><B><FONT face=3D"Tms Rmn"=20
=
color=3D#000000> </FONT></B><B><=
/B><B>=20
<FONT face=3D"Tms Rmn" color=3D#000000 size=3D2>Registered =
Office: Siemens=20
House, Olbury, Bracknell,=20
Berkshire,</FONT></B><FONT face=3D"Tms Rmn" color=3D#000000>=20
</FONT></P></UL></UL>
<P align=3Dleft><B><FONT face=3D"Tms Rmn"=20
=
color=3D#000000> </FONT></B><B><=
/B><B>=20
<FONT face=3D"Tms Rmn" color=3D#000000 size=3D2>RG12 =
8FZ</FONT></B><FONT=20
face=3D"Tms Rmn" color=3D#000000> =
</FONT></P></UL></UL><BR>CONFIDENTIALITY NOTICE:=20
This e-mail message, including any attachments, is for the sole use of =
the=20
intended recipient(s) and may contain confidential and privileged =
information=20
or otherwise be protected by law. Any unauthorized review, use, =
disclosure or=20
distribution is prohibited. If you are not the intended recipient, =
please=20
contact the sender by reply e-mail and destroy all copies of the =
original=20
message. </BLOCKQUOTE></BODY></HTML>
------_=_NextPart_001_01C3DAE6.82D077D4--
|