Veritas-bu

[Veritas-bu] Answer form myself !!!

2002-08-26 05:01:32
Subject: [Veritas-bu] Answer form myself !!!
From: Espen Martinsen <Espen.Martinsen AT mnemonic DOT no> (Espen Martinsen)
Date: Mon, 26 Aug 2002 11:01:32 +0200 (CEST)
Hi,

here was the magic word....

tape-config-list="SONY    SDX-700C","SONY    SDX-700C", "ait-data3";

ait-data3=1,0x36,0,0xd679,4,0x00,0x00,0x00,,0x00,0;


This along with turning OFF dip-switch for term.power on the
robot did it!


I'm now running Veritas Netbackup!


(The emarrasing part was that I found this in Vx dev.config manual...)

RTFM....


Mvh
--------------------------------------------------------------
Espen Martinsen                       Email : esm AT mnemonic DOT no
Mnemonic AS, Waldemar Thranesgt. 77   Phone : +47 2299 9710/00
                                      Mobil : +47 915 88 485
N-0175 Oslo, NORWAY                   Fax   : +47 2299 9701
--------------------------------------------------------------
(PADI AOW 87191)                       http://www.mnemonic.no/
pgp print =  99CD 4027 36F4 0A4F 68DA 2925 327A 5BCF 9C21 F277



<Prev in Thread] Current Thread [Next in Thread>
  • [Veritas-bu] Answer form myself !!!, Espen Martinsen <=