Veritas-bu

[Veritas-bu] Liar Liar Pants on Fire - Error 150

2002-03-25 14:47:53
Subject: [Veritas-bu] Liar Liar Pants on Fire - Error 150
From: kevin.v.vapiwala AT ssmb DOT com (Vapiwala, Kevin V [IT])
Date: Mon, 25 Mar 2002 14:47:53 -0500
I would check out that script and make sure that there isn't anything
strange in their.

-----Original Message-----
From: Donaldson, Mark [mailto:Mark.Donaldson AT experianems DOT com]
Sent: Monday, March 25, 2002 2:17 PM
To: Veritasbu (E-mail)
Subject: RE: [Veritas-bu] Liar Liar Pants on Fire - Error 150



Sorry - mistake in previous post - that should read: 

My backup_exit_notify script capture script records the same error 174. 

This is the master server script, not the client script. 

-Mark 

-----Original Message----- 
From: Vapiwala, Kevin V [IT] [ mailto:kevin.v.vapiwala AT ssmb DOT com
<mailto:kevin.v.vapiwala AT ssmb DOT com> ] 
Sent: Monday, March 25, 2002 11:48 AM 
To: 'Donaldson, Mark'; Veritasbu (E-mail) 
Subject: RE: [Veritas-bu] Liar Liar Pants on Fire - Error 150 


Is there any chance the bpend_notify scripts have been changed on any of the

problem systems? We saw a similar issue and it was due to the client package

that we were depolying having an erroneous bpend_notify script. 

-----Original Message----- 
From: Donaldson, Mark [ mailto:Mark.Donaldson AT experianems DOT com
<mailto:Mark.Donaldson AT experianems DOT com> ] 
Sent: Monday, March 25, 2002 12:56 PM 
To: Veritasbu (E-mail) 
Subject: RE: [Veritas-bu] Liar Liar Pants on Fire - Error 150 


OK - let me ammend this - all things are not as they originally seemed. 
  
Output from bpdbjobs shows error 174 - Media Manager System Error 
  
My bpend_notify script capture script records the same error 174. 
  
The error mailed from the preconfigured mail-the-admin-on-failures part of 
NB sent an error 150. 
  
So - two questions: 
1. Why the discrepency? 
2. what's doing the capture and mailing from the NB preconfigured mail. 
  
-Mark 

-----Original Message----- 
From: Donaldson, Mark [ mailto:Mark.Donaldson AT experianems DOT com
<mailto:Mark.Donaldson AT experianems DOT com> ] 
Sent: Monday, March 25, 2002 10:28 AM 
To: Veritasbu (E-mail) 
Subject: [Veritas-bu] Liar Liar Pants on Fire - Error 150 



Several times now, I've gotten an error 150 (User termination) on my nightly

backups.  However, I know that nobody actually terminated the job. 

This past night's were on filesystems directly (scsi) connected to the 
master/media server so there should be no network or other communication 
issues. 

Is anybody else having this problem?  Know what to do? 

-Mark 

----------------------------------------------------------------------- 
   Mark Donaldson - Sr. Systems Engineer 
   Experian EMS - Denver Colorado 
----------------------------------------------------------------------- 
   Linux? Wasn't that the kid with the blanket? 
-----------------------------------------------------------------------