David, 
what is the level of the firmware of the bridge ?

Take care you have to use the last level...

Pierre 

-----Original Message-----
From: Andrew Shinkarev [mailto:shinkara AT pprd.abbott DOT com]
Sent: vendredi 4 janvier 2002 05:56
To: veritas-bu AT mailman.eng.auburn DOT edu
Subject: Re: [Veritas-bu] STK L700-Drives down


On Thu, Jan 03, 2002 at 03:05:44PM -0600, David A. Chapa wrote:

you can put blank tape with DGXXXX(?) barcode into L700's internal 
slots, they are right under second CAP, and use 
commands from library menu, mount/unmount test should be helpfull, 
if library fails to mount/unmount diag tape then you have problem with
hardware. 
But.. two tape drives at the same time with the same problem.. I don't think
so. 
What kind of tape drives you've got? Are they on the same SCSI chain?

I've got a lot of problems with the STK/CrossRoads bridges. 
That was old STK3200 or 4200 CrossRoads I believe. 
My bridges was logging to fabric with different topology every time.
Be sure you've got the latest firmware. 

The latest firmware level for DLT tape drives is 106. 
I do beleive you need to have 34_2 to run it. 

The latest firmware I heard from STK for L700 is 2.30, it could be 
newer. 

Thanks,
Andrew

 
> here's one for the group to hash out with me.
> 
> STK L700, Solaris 2.6 Master, v 3.4.1, Brocade Switches, Crossroads
Bridges,
> SSO.
> 
> My client has been having an issue with TWO particular drives.  When a
> backup job requests a tape mount, the library satisfies that request, but
> never 'mounts' the tape.  It eventually writes to the syslog that the tape
> is in a down'd drive.  Its only these two drives.
> 
> They have replaced the drives, the bridges and now have asked me to look
> into it.  I took a pretty close look at it today, I think it is hardware.
> The reason I am leaning there, is when I attempted to dismount the tape
from
> the L700 panel, the command failed.  Netbackup at that point had already
> given up on the two drives and I had already killed the backup jobs, so
> there was nothing special going on with the NBU server.
> 
> Any thoughts out there?
> 
> Thanks
> 
> David
> 
> <><><><><><><><><><><><><><><><><><><><>
> David A. Chapa
> NetBackup Consultant
> DataStaff, Inc.
> http://www.consulting.datastaff.com
> 847 413 1144
> ---------------------------------------
> NBU-LSERV AT datastaff DOT com - Adv. Scripting
> http://www.xbpadm-commands.com
> 
> _______________________________________________
> Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
> http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

-- 
----
Andrew Shinkarev
Network Systems Specialist
Abbott Laboratories
(847) 9387559
shinkara AT pprd.abbott DOT com
_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

------_=_NextPart_001_01C19501.CC8552C0
Content-Type: text/html;
        charset="iso-8859-1"

<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 3.2//EN">
<HTML>
<HEAD>
<META HTTP-EQUIV="Content-Type" CONTENT="text/html; charset=iso-8859-1">
<META NAME="Generator" CONTENT="MS Exchange Server version 5.5.2653.12">
<TITLE>RE: [Veritas-bu] STK L700-Drives down</TITLE>
</HEAD>
<BODY>

<P><FONT SIZE=2>David, </FONT>
<BR><FONT SIZE=2>what is the level of the firmware of the bridge ?</FONT>
</P>

<P><FONT SIZE=2>Take care you have to use the last level...</FONT>
</P>

<P><FONT SIZE=2>Pierre </FONT>
</P>

<P><FONT SIZE=2>-----Original Message-----</FONT>
<BR><FONT SIZE=2>From: Andrew Shinkarev [<A HREF="mailto:shinkara AT 
pprd.abbott DOT com">mailto:shinkara AT pprd.abbott DOT com</A>]</FONT>
<BR><FONT SIZE=2>Sent: vendredi 4 janvier 2002 05:56</FONT>
<BR><FONT SIZE=2>To: veritas-bu AT mailman.eng.auburn DOT edu</FONT>
<BR><FONT SIZE=2>Subject: Re: [Veritas-bu] STK L700-Drives down</FONT>
</P>
<BR>

<P><FONT SIZE=2>On Thu, Jan 03, 2002 at 03:05:44PM -0600, David A. Chapa 
wrote:</FONT>
</P>

<P><FONT SIZE=2>you can put blank tape with DGXXXX(?) barcode into L700's 
internal </FONT>
<BR><FONT SIZE=2>slots, they are right under second CAP, and use </FONT>
<BR><FONT SIZE=2>commands from library menu, mount/unmount test should be 
helpfull, </FONT>
<BR><FONT SIZE=2>if library fails to mount/unmount diag tape then you have 
problem with hardware. </FONT>
<BR><FONT SIZE=2>But.. two tape drives at the same time with the same problem.. 
I don't think so. </FONT>
<BR><FONT SIZE=2>What kind of tape drives you've got? Are they on the same SCSI 
chain?</FONT>
</P>

<P><FONT SIZE=2>I've got a lot of problems with the STK/CrossRoads bridges. 
</FONT>
<BR><FONT SIZE=2>That was old STK3200 or 4200 CrossRoads I believe. </FONT>
<BR><FONT SIZE=2>My bridges was logging to fabric with different topology every 
time.</FONT>
<BR><FONT SIZE=2>Be sure you've got the latest firmware. </FONT>
</P>

<P><FONT SIZE=2>The latest firmware level for DLT tape drives is 106. </FONT>
<BR><FONT SIZE=2>I do beleive you need to have 34_2 to run it. </FONT>
</P>

<P><FONT SIZE=2>The latest firmware I heard from STK for L700 is 2.30, it could 
be </FONT>
<BR><FONT SIZE=2>newer. </FONT>
</P>

<P><FONT SIZE=2>Thanks,</FONT>
<BR><FONT SIZE=2>Andrew</FONT>
</P>

<P><FONT SIZE=2>&nbsp;</FONT>
<BR><FONT SIZE=2>&gt; here's one for the group to hash out with me.</FONT>
<BR><FONT SIZE=2>&gt; </FONT>
<BR><FONT SIZE=2>&gt; STK L700, Solaris 2.6 Master, v 3.4.1, Brocade Switches, 
Crossroads Bridges,</FONT>
<BR><FONT SIZE=2>&gt; SSO.</FONT>
<BR><FONT SIZE=2>&gt; </FONT>
<BR><FONT SIZE=2>&gt; My client has been having an issue with TWO particular 
drives.&nbsp; When a</FONT>
<BR><FONT SIZE=2>&gt; backup job requests a tape mount, the library satisfies 
that request, but</FONT>
<BR><FONT SIZE=2>&gt; never 'mounts' the tape.&nbsp; It eventually writes to 
the syslog that the tape</FONT>
<BR><FONT SIZE=2>&gt; is in a down'd drive.&nbsp; Its only these two 
drives.</FONT>
<BR><FONT SIZE=2>&gt; </FONT>
<BR><FONT SIZE=2>&gt; They have replaced the drives, the bridges and now have 
asked me to look</FONT>
<BR><FONT SIZE=2>&gt; into it.&nbsp; I took a pretty close look at it today, I 
think it is hardware.</FONT>
<BR><FONT SIZE=2>&gt; The reason I am leaning there, is when I attempted to 
dismount the tape from</FONT>
<BR><FONT SIZE=2>&gt; the L700 panel, the command failed.&nbsp; Netbackup at 
that point had already</FONT>
<BR><FONT SIZE=2>&gt; given up on the two drives and I had already killed the 
backup jobs, so</FONT>
<BR><FONT SIZE=2>&gt; there was nothing special going on with the NBU 
server.</FONT>
<BR><FONT SIZE=2>&gt; </FONT>
<BR><FONT SIZE=2>&gt; Any thoughts out there?</FONT>
<BR><FONT SIZE=2>&gt; </FONT>
<BR><FONT SIZE=2>&gt; Thanks</FONT>
<BR><FONT SIZE=2>&gt; </FONT>
<BR><FONT SIZE=2>&gt; David</FONT>
<BR><FONT SIZE=2>&gt; </FONT>
<BR><FONT SIZE=2>&gt; 
&lt;&gt;&lt;&gt;&lt;&gt;&lt;&gt;&lt;&gt;&lt;&gt;&lt;&gt;&lt;&gt;&lt;&gt;&lt;&gt;&lt;&gt;&lt;&gt;&lt;&gt;&lt;&gt;&lt;&gt;&lt;&gt;&lt;&gt;&lt;&gt;&lt;&gt;&lt;&gt;</FONT>
<BR><FONT SIZE=2>&gt; David A. Chapa</FONT>
<BR><FONT SIZE=2>&gt; NetBackup Consultant</FONT>
<BR><FONT SIZE=2>&gt; DataStaff, Inc.</FONT>
<BR><FONT SIZE=2>&gt; <A HREF="http://www.consulting.datastaff.com"; 
TARGET="_blank">http://www.consulting.datastaff.com</A></FONT>
<BR><FONT SIZE=2>&gt; 847 413 1144</FONT>
<BR><FONT SIZE=2>&gt; ---------------------------------------</FONT>
<BR><FONT SIZE=2>&gt; NBU-LSERV AT datastaff DOT com - Adv. Scripting</FONT>
<BR><FONT SIZE=2>&gt; <A HREF="http://www.xbpadm-commands.com"; 
TARGET="_blank">http://www.xbpadm-commands.com</A></FONT>
<BR><FONT SIZE=2>&gt; </FONT>
<BR><FONT SIZE=2>&gt; _______________________________________________</FONT>
<BR><FONT SIZE=2>&gt; Veritas-bu maillist&nbsp; -&nbsp; Veritas-bu AT 
mailman.eng.auburn DOT edu</FONT>
<BR><FONT SIZE=2>&gt; <A 
HREF="http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu"; 
TARGET="_blank">http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu</A></FONT>
</P>

<P><FONT SIZE=2>-- </FONT>
<BR><FONT SIZE=2>----</FONT>
<BR><FONT SIZE=2>Andrew Shinkarev</FONT>
<BR><FONT SIZE=2>Network Systems Specialist</FONT>
<BR><FONT SIZE=2>Abbott Laboratories</FONT>
<BR><FONT SIZE=2>(847) 9387559</FONT>
<BR><FONT SIZE=2>shinkara AT pprd.abbott DOT com</FONT>
<BR><FONT SIZE=2>_______________________________________________</FONT>
<BR><FONT SIZE=2>Veritas-bu maillist&nbsp; -&nbsp; Veritas-bu AT 
mailman.eng.auburn DOT edu</FONT>
<BR><FONT SIZE=2><A 
HREF="http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu"; 
TARGET="_blank">http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu</A></FONT>
</P>

</BODY>
</HTML>
------_=_NextPart_001_01C19501.CC8552C0--

<Prev in Thread] Current Thread [Next in Thread>