We have been running firmware version 106 successfully on DLT7000 for
the last two weeks.  Our Master/Media server is Windows 2000 Server at
service pack 2, NetBackup Data Center 3.4.1 at the 3.4.1-1 service pack.
Our library is a STK9740 with 10 drives.

Ed Abajo
Enterprise Server Analyst,
RIS Enterprise Server Support 
Tricon Global Restaurants, Inc.
*       Voice       949.863.8353
*       Fax     949.863.4507
*       Pager   888.page.yum(724.3986)
*       Email   EAbajo AT tacobell DOT com



-----Original Message-----
From: "Raghavan; Shyam" [mailto:Shyam.Raghavan AT weac DOT com] 
Sent: Thursday, November 15, 2001 9:59 AM
To: Veritas-bu AT mailman.eng.auburn DOT edu
Cc: "'Miriam Ben-Haim'" 
Subject: RE: (Veritas-bu) DLT 7000 firmware version


Just wondering if any one else  in the list runs firmware version 106
successfully on DLT7000 ?

Many thanks Mariam to point out the previous discussion on "status 83".

Thanks,
Shyam.

-----Original Message-----
From: Miriam Ben-Haim [mailto:miriam AT techunix.technion.ac DOT il]
Sent: Thursday, November 15, 2001 12:15 AM
To: Raghavan, Shyam
Cc: 'Veritas-bu AT mailman.eng.auburn DOT edu'
Subject: Re: [Veritas-bu] DLT 7000 firmware version


On Wed, 14 Nov 2001, Raghavan, Shyam wrote:

>I am planning to upgrade the DLT 7000 microcode  from rev 101 to 106.  
>The drives are all internal drives of an SUN L700 unit Any body has any

>good or bad experience with rev 106 ?
>
>I use Veritas Netbackup Datacenter 3.4 on Solaris 2.6


We had a short discussion on that 2 days ago on this list. Look under
the subject "Media errors (status 83)".

In short - it seems that microcode 106 causes problems with the data
tapes, while it saves on the cleaning tapes. Obviously it is better to
waste some cleaning tapes (stay with the old microcode).

The subject is still checked with STK.



     Miriam


~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 Miriam Ben-Haim                 E-mail: miriam AT technion.ac DOT il
 Unix Systems                    Phone : +972-4-8292177
 Taub Computer Center            Fax   : +972-4-8236212
 Technion - Israel Institute of Technology, Haifa 32000, ISRAEL

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


---------------------------- 
This communication is confidential and may be legally privileged.  If you
are not the intended recipient, (i) please do not read or disclose to
others, (ii) please notify the sender by reply mail, and (iii) please delete
this communication from your system.  Failure to follow this process may be
unlawful.  Thank you for your cooperation. 
---------------------------- 

<Prev in Thread] Current Thread [Next in Thread>
  • [Veritas-bu] RE: (Veritas-bu) DLT 7000 firmware version, Abajo, Ed <=