[Veritas-bu] Master/Media Server System Resource Setting?
2001-05-18 17:33:11
Subject: |
[Veritas-bu] Master/Media Server System Resource Setting? |
From: |
rob AT colltech DOT com (Rob Worman) |
Date: |
Fri, 18 May 2001 16:33:11 -0500 |
"Lundy, Mark" wrote:
>
> We have been tasked to provide our systems admins with the Veritas
> recommended settings for IPC and any other system resources for SunOS 5.6
> and HP-UX11.00 Master and Media Servers. Does anyone have this or can point
> me to where they are defined? Thanks.
>
> Mark
FWIW, I got this from Veritas support last week.
They are obviously written with Solaris in mind, but I think you can
just remove the "blah_" text and you'll have HPUX kernel parameters.
Like David suggested, I'd check out the rules of thumb first - kernel
variables are not something that you can always generalize about.
#
#Kernel Parameter recommendations for NBU media server
#
maxusers=32
#Shared Memory
shminfo_shmmin=1
shminfo_shmmni=220
shminfo_shmseg=100
shminfo_shmmax=8388608
# system queues, semaphores
seminfo_semume=64
seminfo_semmap=64
seminfo_semopm=32
seminfo_semmni=1024
seminfo_semmns=1024
seminfo_semmnu=1024
seminfo_semmsl=60
# message queues
msginfo_msgmap=512
msginfo_msgmax=8192
msginfo_msgmnb=65536
msginfo_msgmni=256
msginfo_msgssz=8
msginfo_msgtql=512
msginfo_msgseg=8192
|
|
|