[Veritas-bu] changing tape libraries at hot site
2001-02-05 13:23:37
Subject: |
[Veritas-bu] changing tape libraries at hot site |
From: |
David A. Chapa david AT datastaff DOT com |
Date: |
Mon, 5 Feb 2001 10:23:37 -0800 (PST) |
Shouldn't be a problem. I can't think of any show
stoppers.
You'll just want to make sure that you have your robot
configured properly at the hot site (robnum, devfile,
etc.)
Perhaps one of the things that I would do after you
recover the databases at your hot site would be to move
all of the tapes to NON-ROBOTIC or STANDALONE then Auto-
Inventory the library.
other than that I think you should be okay.
David
Quoting Daniel Monjar <dam AT orgtek DOT com>:
> what would be involved with changing tape libraries
at a disaster
> recovery test? Say I'm using a Quantum/ATL robot
here and have to use
> a Storage-Tek robot there. Is this a large problem?
>
> --
> Daniel Monjar (mailto:dmonjar AT orgtek DOT com)
> "Never underestimate the power of stupid people in
large groups."
>
> _______________________________________________
> Veritas-bu maillist - Veritas-
bu AT mailman.eng.auburn DOT edu
>
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-
bu
>
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
David A. Chapa
Consulting Manager
DataStaff, Inc.
847 413 1144
|
|
|