EMC NetWorker discussion <NETWORKER AT LISTSERV.TEMPLE DOT EDU> wrote on
02/07/2008 02:01:00 PM:
> In regard to: [Networker] Confused about mminfo query, MIchael Leone
said...:
> You need to specify how wide the field should be for savetime, via
> something like "savetime(21)". The (NN) method works for most fields
> that I've tried, which can be useful for some reports.
That was it, thanks. And for certain sizing fields (i.e., totalsize),
setting width to (2) shows size in MB/GB, which is a lot easier to read
than bytes, when you're dealing with 500G+ ...
>
> > Main question: when I run:
> >
> > mminfo -r "ssid,cloneid,savetime" -q
"client=%machine%,volume=%tapevol%"
> >
> > I get the same results. How is that possible?
>
> Off the top of my head, I wouldn't think it would be, but I'm not that
> familiar with AFTDs. I would try adding more fields to the report
> (especially copies,client,volume) and see if that points out any obvious
> issues. I'm suspicious it has something to do with the volume part of
That was it. When I printed the "copies" field, I saw that the value was
3. So of course, that would match both queries (because it was more than
1).
Sorry for the confusion.
To sign off this list, send email to listserv AT listserv.temple DOT edu and
type "signoff networker" in the body of the email. Please write to
networker-request AT listserv.temple DOT edu if you have any problems with this
list. You can access the archives at
http://listserv.temple.edu/archives/networker.html or
via RSS at http://listserv.temple.edu/cgi-bin/wa?RSS&L=NETWORKER
|