Re: [Networker] Jukebox CAP door status
2007-08-14 14:36:08
> I've noticed that NetWorker 7.3.2 logs when the tape library cartridge
> access port door is opened and closed. Does anyone know if there is a
> command to get the status of the door? I can't see any of the SJI commands
> that look like they provide that. Thanks!
Is there no difference in the output of say 'sjirelem' or 'sjirdtag'
between open and closed? I would have thought that some of the values
in the IMPORT/EXPORT lines would flip when the door is open.
On my test library (an ancient ATL DLT model with one slot)
When door is closed:
# sjirelem 2.0.0
[...]
Element Data for 2.0.0, Element Type IMPORT/EXPORT:
Elem[001]: pres_val=1 inp_enab=1 exp_enab=1 access=1 full=0 imp_exp=0
When door is open:
[...]
Element Data for 2.0.0, Element Type IMPORT/EXPORT:
Elem[001]: pres_val=0 inp_enab=1 exp_enab=1 access=0 full=0 imp_exp=0
I can believe that it doesn't do the same thing on all libraries, and my
man page doesn't explain all implications of the 'access' field.
--
Darren Dunham ddunham AT taos DOT com
Senior Technical Consultant TAOS http://www.taos.com/
Got some Dr Pepper? San Francisco, CA bay area