Hello,
If the Drives are attached via Fiber, you may be able to load FC managment
software ( or updading Bios) to enable Persistant binding , that will help
with drives getting off sequience. ( Sansurferpro for Qlogic)
Also, newer IBM drives now include a paramenter to bind drive order
( check ibm site , driver level 6.6.2-Readme, atlest for windows platform).
finally, if you have 7.3 level networker, jbconfig includes eliment number
during setup, if you combine that with sjimm output, you should be able to
achive correct drive order.