Networker

Re: [Networker] JBCONFIG_i2K Problems

2006-03-09 14:41:25
Subject: Re: [Networker] JBCONFIG_i2K Problems
From: "Stewart, Kathy" <Kathy.Stewart AT RODALE DOT COM>
To: NETWORKER AT LISTSERV.TEMPLE DOT EDU
Date: Thu, 9 Mar 2006 14:33:42 -0500
First off, let me say that I have been fighting with this since March
2005.

It has only gotten better since I had a upper level engineer get
involved.  He ran a webex session and changed the way that the HBAs and
Scalar were mapped.  I have 10 drives shared between 6 servers, so I
have 60 instances of tape drives that I have to reconfigure when there
is a problem.  Use jbedit, it will save you a ton of time. 


You need to make sure that your Scalar has the lastest firmware.
Have ADIC make sure that all your HBAs and Scalar mappings are correct.
Make sure you are restarting your Scalar correctly.

I still have issues, but they swap in groups instead of all over the
place.



Kathy Stewart
Rodale, Inc
Emmaus, PA
Kathy.stewart AT rodale DOT com



 

-----Original Message-----
From: Legato NetWorker discussion [mailto:NETWORKER AT LISTSERV.TEMPLE DOT EDU]
On Behalf Of Fazil Saiyed
Sent: Tuesday, March 07, 2006 10:46 AM
To: NETWORKER AT LISTSERV.TEMPLE DOT EDU
Subject: [Networker] JBCONFIG_i2K Problems

Hello,
I am having hard time configuring server (Windows 2003-64 bit-Dell PE
6850).
Windows keeps rearranging Drive order  ( IBM-LTO2) after drivers are
loaded, i see that the Networker 7.2.1 does not like the drive order
which i create and i have problems with backups, recover ( even though
the tape required for restore are inventoried and avallable in the lib,
they are not being loaded automatically.
Is there better commands or utilities that can quiry drive order,
Jbconfig can run under. Need immediate Help our enviroment.
i2K-LTO2.
CDI Flag set to Not used.
Errors: Adic resource out of Sync.


H:\>inquire
Could not start a Removable Storage session (0x00000422).
[email protected]:HL-DT-STCDRW/DVD GCC4244B101|CD-ROM
[email protected]:ADIC    Scalar i2000    300A|Autochanger (Jukebox)
                                           S/N: ADIC203101904_LL0
                                           ATNN:ADIC    203101904_L

[email protected]:IBM     ULTRIUM-TD2     53Y2|Tape, \\.\Tape0
[email protected]:IBM     ULTRIUM-TD2     53Y2|Tape, \\.\Tape1
[email protected]:IBM     ULTRIUM-TD2     53Y2|Tape, \\.\Tape6
[email protected]:IBM     ULTRIUM-TD2     53Y2|Tape, \\.\Tape7
[email protected]:IBM     ULTRIUM-TD2     53Y2|Tape, \\.\Tape2
[email protected]:IBM     ULTRIUM-TD2     53Y2|Tape, \\.\Tape3
[email protected]:IBM     ULTRIUM-TD2     53Y2|Tape, \\.\Tape4
[email protected]:IBM     ULTRIUM-TD2     53Y2|Tape, \\.\Tape5
[email protected]:PE/PV   1x5 SCSI BP     1.0 |Processor
[email protected]:  RAID   DummyDevice    0000|Unknown Device Type
[email protected]:PERC     LD  0 PERCRAID     |Disk
[email protected]:PERC     LD  1 PERCRAID     |Disk

++++++++++++++++
D:\>jbconfig
         1) Configure an AlphaStor/SmartMedia Jukebox.
         2) Configure an Autodetected SCSI Jukebox.
         3) Configure an Autodetected NDMP SCSI Jukebox.
         4) Configure an SJI Jukebox.
         5) Configure an STL Silo.
         6) Configure a Microsoft Removable Storage Jukebox.

What kind of Jukebox are you configuring? [1] 2 Installing 'Standard
SCSI Jukebox' jukebox - [email protected].

What name do you want to assign to this jukebox device? ADIC Turn
NetWorker auto-cleaning on (yes / no) [yes]? y The drives in this
jukebox cannot be auto-configured with the available  information. You
will need to provide the path for the drives.

Is (any path of) any drive intended for NDMP use? (yes / no) [no] n Is
any drive going to have more than one path defined? (yes / no) [no] n

Please enter the device path information in one of the following
formats:

        \\.\Tape0 --for local path or
        host:device-path --for remote node or
        host:drive-letter:directory path --for Windows disk file

Drive  1, element 256
Drive path ? \\.\Tape0

Drive  2, element 257
Drive path ? \\.\Tape1

Drive  3, element 258
Drive path ? \\.\Tape6

Drive  4, element 259
Drive path ? \\.\Tape7

Drive  5, element 260
Drive path ? \\.\Tape2

Drive  6, element 261
Drive path ? \\.\Tape3

Drive  7, element 262
Drive path ? \\.\Tape4

Drive  8, element 263
Drive path ? \\.\Tape5


Please select the appropriate drive type number:
  1) 3480                  20) 9490                  39) LTO Ultrium-3
  2) 3570                  21) 9840                  40) optical
  3) 3590                  22) 9840b                 41) qic
  4) 3592                  23) 9840C                 42) SAIT-1
  5) 4890                  24) 9940                  43) SD3
  6) 4mm                   25) 9940B                 44) sdlt
  7) 4mm 12GB              26) adv_file              45) sdlt320
  8) 4mm 20GB              27) dlt                   46) sdlt600
  9) 4mm 4GB               28) dlt1                  47) SLR
 10) 4mm 8GB               29) dlt7000               48) tkz90
 11) 4mm DAT72             30) dlt8000               49) travan10
 12) 8mm                   31) dst (NT)              50) tz85
 13) 8mm 20GB              32) dtf                   51) tz86
 14) 8mm 5GB               33) dtf2                  52) tz87
 15) 8mm AIT               34) file                  53) tz88
 16) 8mm AIT-2             35) himt                  54) tz89
 17) 8mm AIT-3             36) logical               55) tz90
 18) 8mm AIT-4             37) LTO Ultrium           56) tzs20
 19) 8mm Mammoth-2         38) LTO Ultrium-2         57) VXA

Enter the drive type of drive 1? 38
Are all the drives the same model? (yes / no) [yes] y


Jukebox has been added successfully

The following configuration options have been set:

   > Jukebox description to the control port and model.
   > Autochanger control port to the port at which we found it.
   > Networker managed tape autocleaning on.
   > Barcode reading to on.
   > Volume labels that match the barcodes.
   > Slot intended to hold cleaning cartridge to 102.  Please insure
that a
     cleaning cartridge is in that slot
   > Number of times we will use a new cleaning cartridge to 50.
   > Cleaning interval for the tape drives to 6 months.

You can review and change the characteristics of the autochanger and its
associated devices using nwadmin.

Would you like to configure another jukebox? (yes/no) [no]n

D:\>

To sign off this list, send email to listserv AT listserv.temple DOT edu and
type "signoff networker" in the body of the email. Please write to
networker-request AT listserv.temple DOT edu if you have any problems wit this
list. You can access the archives at
http://listserv.temple.edu/archives/networker.html or via RSS at
http://listserv.temple.edu/cgi-bin/wa?RSS&L=NETWORKER

To sign off this list, send email to listserv AT listserv.temple DOT edu and 
type "signoff networker" in the
body of the email. Please write to networker-request AT listserv.temple DOT edu 
if you have any problems
wit this list. You can access the archives at 
http://listserv.temple.edu/archives/networker.html or
via RSS at http://listserv.temple.edu/cgi-bin/wa?RSS&L=NETWORKER

<Prev in Thread] Current Thread [Next in Thread>